Back to search

University of Southampton

Automatic reference region localisation in positron emission tomography

Abstract

dc:description.abstract

<p>This thesis addresses the automatic extraction of a reference tissue region, devoid of receptor sites, which can then be used as an input for a reference tissue model, allowing for the quantification of receptor sites. It is shown that this segmentation can be determined from the time-activity curves associated with each voxel within the 3D volume, using modern machine learning methods.</p> <p>Previously, supervised learning techniques have not been considered in PET reference region extraction. In this thesis, two new methods are proposed to incorporate expert knowledge and the image models with the data: a hierarchical method and a semi-supervised image segmentation framework. Markov random field (MRF) models are used as a stochastic image model to specify the spatial interactions. The first method uses a Bayesian neural network with a hierarchical Markov random field model. The second method advances the first method by employing a semi-supervised image segmentation framework to combine the fidelity of supervised data with the quantity of unsupervised data. This is realised by a three-level image model structure with probability distributions specifying the interconnections. This has the advantages for the generalisation performance and hence the reduction of bias in PET reference region extraction. An Expectation Maximisation based algorithm is proposed to solve this combined learning problem. The performance of unsupervised, supervised and semi-supervised classification in temporal models and spatio-temporal models are compared, using both simulated and [<sup>11</sup>C]<i>(R)</i>-PK11195 PET data. In conclusion, it shows that the inclusion of expert knowledge greatly reduces the uncertainty in the segmentation with the new semi-supervised framework achieving substantial performance gains over the other methods.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chen, Jun L

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Chen, Jun L. Automatic reference region localisation in positron emission tomography. doctoral thesis, University of Southampton, 2003.