Back to search

University of Southampton

Recovery voltage in transformer oil-paper insulation diagnosis

Abstract

dc:description.abstract

<p><span style='letter-spacing:-.15pt'>Using recovery voltage to assess the state of electrical insulation has been a very </span>popular method among engineers in the power industry. As a result of its popularity, <span style='letter-spacing:-.1pt'>there is growing interest among engineers to quantify and to have more thorough </span>understanding of the underlying physical processes. The conventional method of <span style='letter-spacing: -.15pt'>measuring the recovery voltage does not record all of the information.</span></p> <p>While this is understandable for practical purposes it is not helpful for <span style='letter-spacing:-.15pt'>understanding the recovery voltage as a physical process. Therefore a new experimental </span>rig has been built to study the recovery voltage in oil-paper systems. This new <span style='letter-spacing:-.2pt'>experiment records the entire voltage profile for detail analysis. The system also controls </span><span style='letter-spacing: -.15pt'>the level of moisture and temperature of the insulation material to study the influence of each factor on the recovery voltage of oil-paper insulation. This simplified version of an </span>insulation system in the experiment will help to understand the recovery voltage as an <span style='letter-spacing:-.1pt'>electrical response of insulation material avoiding complication of a real transformer. </span><span style='letter-spacing: -.2pt'>Various standard and non-standard measurements have been performed on the dry paper and oil-paper samples. The results are discussed and a model is proposed based on these </span><span style='letter-spacing:-.15pt'>results. The measurement results obtained in a series of experiments exposed two very </span>important shortcomings of the commonly accepted model. Firstly it fails to explain <span style='letter-spacing:-.1pt'>many variations in the observed recovery voltage and secondly the parameters in the </span>circuit representation lack direct physical interpretation.</p> <p><span style='letter-spacing:-.2pt'>A new model is proposed based on indirect evidences inferred from the results of </span>the experiments and published properties of oil-paper insulation using other measurement techniques. The new model is built by assuming that the bulk dipole <span style='letter-spacing:-.15pt'>polarisation plays less significant role in the formation of recovery voltage. Instead, the </span>interfacial charge transfers and charge diffusion on the surface of paper are used to <span style='letter-spacing:-.1pt'>explain the formation of recovery voltage in the oil-paper insulation system. The new model fits the experimental results well using small number of parameters with direct physical interpretations. This qualitative leap in the understanding of recovery voltage </span><span style='letter-spacing:-.15pt'>will help engineers to interpret the results of field measurements more accurately.</span></p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kuang, Ye Chow

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kuang, Ye Chow. Recovery voltage in transformer oil-paper insulation diagnosis. doctoral thesis, University of Southampton, 2004.