Back to search

University of Southampton

Partial discharge monitoring of power transformers

Abstract

dc:description.abstract

<p><span style='letter-spacing:-.4pt'>This thesis is concerned with an approach to the monitoring and measurement of partial </span>discharges within power transformers, including the classification and recognition of partial <span style='letter-spacing:-.25pt'>discharge signals in the both frequency and time domains from bushing tap points via </span><span style='letter-spacing:-.35pt'>RFCT (Radio Frequency Current Transducer), the propagation characteristics of high </span><span style='letter-spacing:-.4pt'>frequency signals and real partial discharge signals within a transformer model with a </span><span style='letter-spacing:-.25pt'>bandwidth of up to 200 MHz, and also the techniques of de-noising, diagnosis and </span>localization of internal partial discharge.</p> <p><span style='letter-spacing:-.4pt'>The principle proposed based on the fact that an internal partial discharge signal of an oil-</span><span style='letter-spacing:-.35pt'>filled power transformer may propagate along a winding and its leads to reach a bushing </span><span style='letter-spacing: -.45pt'>core bar, the bushing acting like a capacitor can transfer the high frequency components of </span><span style='letter-spacing:-.35pt'>the partial discharge signal across to its tap point, using a sensor the transferred partial </span><span style='letter-spacing:-.4pt'>discharge signal can be detected. The developed technique allows the partial discharge </span>monitoring and measurement of power transformers to be carried out by using a RFCT as a <span style='letter-spacing:-.2pt'>sensor at taps of transformer bushings. The obtained data was stored, displayed and </span><span style='letter-spacing: -.25pt'>analysed using digital equipment. This approach was applied to the auto-transformer </span><span style='letter-spacing:-.45pt'>SGT3A at Northfleet Substation, </span><span style='letter-spacing:-.45pt'>West London</span><span style='letter-spacing:-.45pt'>, and was also verified on the transformer </span>model at the High Voltage Laboratory, UMIST.</p> <p><span style='letter-spacing:-.2pt'>Centred on this principle, the sensitivities of a 60kV transformer bushing, RFCTs, </span><span style='letter-spacing:-.4pt'>transformer oil, transformer windings and a transformer model with an interleaved disc </span><span style='letter-spacing: -.15pt'>winding and a plain disc winding were investigated by studying the propagation </span><span style='letter-spacing:-.45pt'>characteristics of high frequency signals within them. The classification and characteristics of partial discharges within power transformers and out of the 60kV bushing tap were also </span><span style='letter-spacing:-.25pt'>studied in both time and frequency domains. A major aspect of this work was the </span><span style='letter-spacing:-.45pt'>experimentally confirmed hypothesis that high frequency components of internal partial </span><span style='letter-spacing: -.4pt'>discharge signals pass through the winding and bushing with little attenuation and can be detected at the bushing tap point. The feasibility of software techniques required to realize </span><span style='letter-spacing: -.35pt'>de -noising from measured signals in the field was investigated. A transfer function has </span><span style='letter-spacing:-.3pt'>been developed for the transformer model based on its frequency response from 0-200 </span><span style='letter-spacing:-.25pt'>MHz. This linear model has a significantly wider bandwidth than previous published </span><span style='letter-spacing:-.1pt'>models and greatly improves the prospect of diagnosis and localization of partial </span>discharges within power transformers.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Han, Baojia

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Han, Baojia. Partial discharge monitoring of power transformers. doctoral thesis, University of Southampton, 2004.