Back to search

University of Southampton

Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains

Abstract

dc:description.abstract

<p>A fully mechanical test rig was developed to simulate a series of passive stability tests; the rig allowed the strains of the primary knee ligaments to be altered as well as coronal plane alignment. In addition, the rig was used to conduct contact pressure measurements using Tekscan instrumentation. It was shown that implant design played a significant role in the passive stability of the replaced knee, and that each design was affected differently by altered ligament strains and component alignment. Assessment of stability in a certain plane was able to highlight specific surgical inaccuracies; for example, ligament imbalance was best detected by varus-valgus stability testing.</p> <p>In phase two of the research, computational finite element (FE) models were created for validation against the experimental test results. Using explicit FE analysis the experimental passive stability testing was simulated. There was a good agreement between the FE simulations and the experimental results in terms of displacements, rotations and contact pressures.</p> <p>The final stage of the research focused on simulating normal gait using the FE models. After recording the kinematics and contact pressures for the idealised knees, gait was assessed with altered ligament strains and component malalignment. Results from the present study showed that imbalanced ligaments did not significantly affect the gait kinematics or contact pressures; however the force distribution across the knee was altered. It has been reported that post-operative malalignment may be due to imbalanced ligament strains; this correlates with the present research which showed that immediate post-operative malalignment could occur due to an uneven force distribution caused by imbalanced ligaments. Slight malalignment did not however significantly alter the kinematics during gait, but did affect the contact pressure distribution.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Curtis, Neil

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Curtis, Neil. Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains. doctoral thesis, University of Southampton, 2004.