Back to search

University of Southampton

Oxygen reduction at microelectrodes : application to the dissolved oxygen sensor for in situ oceanographic measurements

Abstract

dc:description.abstract

<p>This work describes the development of an accurate and reliable electrochemical dissolved oxygen sensor for oceanographic measurements. The amperometric response of the sensor gives direct information on the concentration of dissolved oxygen, which is reduced at a microdisc cathode to peroxide species and water. A number of parameters including electrode material, potential waveform, the apparent number of electrons (<i>n</i><sub>app</sub>) as well as temperature, salinity and flow effects, are investigated.</p> <p>Parameters for platinum microcathodes electrochemical cleaning are reported, which yield very stable amperometric response under continuous operation, with a maximum standard deviation of the limiting current under 1.5%. An automated calibration method developed to accurately characterise the electrodes is described. Excellent linearity is obtained for electrodes tested and in each case <i>n</i><sub>app </sub>is extracted. As an alternative to calibration, an analytical treatment which accounts for temperature and salinity effects is given to calculate the dissolved oxygen concentration directly from the limiting current.</p> <p>A prototype oceanographic dissolved oxygen sensor which includes flow control arrangement is described. Its performance in field trials carried out during the RRS Discovery transatlantic cruise D279 is presented. The results of eight deep sea deployments are compared with the dissolved oxygen – depth profiles obtained by onboard Winkler titration of the samples bottled at discrete depths.</p> <p>Two approaches alternative to the limiting current measurements are also reported, with the aim to perform the measurements directly in the water column on a moving probe: the vibration of the microelectrode to create controlled forced convection and transient measurements with the potential step durations down to 1 ms. The latter is shown to be capable of quantitative determination of oxygen, while showing high immunity to the external flow.</p>

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Southampton
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sosna, Maciej

Rights

Language dc:language
English, eng

Chain of custody

source
Harvested from
University of Southampton
Base URL
eprints.soton.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Sosna, Maciej. Oxygen reduction at microelectrodes : application to the dissolved oxygen sensor for in situ oceanographic measurements. doctoral thesis, University of Southampton, 2006.