Abstract
dc:description.abstract<p><b><span >Method: </span></b><span >Three experiments were designed to examine variables likely to affect the accuracy of measuring FBF by venous occlusion plethysmography. In a further four experiments, FBF was measured before, during and after the application of a 2 N force and vibration at 16, 31.5, 63, 125, 250, and 315 Hz at acceleration magnitudes from 0 to 15 ms<sup>-2</sup> r.m.s. Healthy male subjects were used in all experiments.</span></p> <p><b><span >Results: </span></b><span >In the first experiment in Chapter 4, FBF was found to be similar whether measured on a single finger or simultaneously on all five fingers of a hand.</span></p> <p><span >Differences in FBF between two plethysmographs (Medimatic Digitmatic DM2000 and <i>HVLab</i> </span><span >multi-channel plethysmograph) found in the second experiment in Chapter 4, were partially explained by the compensation for the resistances of the cables connected to the strain gauges.</span></p> <p><span >The third experiment, in Appendix B, found no effect on FBF of whole-body vibration (1.0 ms<sup>-2</sup> r.m.s. at 8 Hz or 4 ms<sup>-2</sup> r.m.s. at 63 Hz) during or after vibration.</span></p> <p><span >The experiments in Chapters 5 and 6 found that a 2 N push force applied to the finger reduced FBF in the exposed finger, compared to pre-exposure blood flow. However, a 2 N push force applied to one or two palms did not affect FBF in either hand.</span></p> <p><span >With the effect of push force minimised in the experiments in Chapters 6 to 8 there was no difference in FBF between the exposed and the unexposed hand during or after exposure to vibration. Also, there was vasoconstriction without preliminary strong vasodilation after the end of exposure.</span></p> <p><span >Vibration of two hands generally caused a similar vasoconstriction as vibration of one hand in Chapter 8.</span></p> <p><span >The results are consistent with vibration activating centrally mediated vasoconstriction in both hands during and after vibration exposure. The mechanism controlling the vasoconstriction is dependent on the frequency and the magnitude of the vibration.</span></p>
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D.
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of Southampton
- Year dc:date.issued
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Welsh, Alexandra Jane Lawson
Rights
- Language dc:language
- English, eng