University of Southampton
Electrochemical capacitance behaviour of Laser-Induced Graphene (LIG) with and without metallic nanoparticle loading
Abstract
dc:description.abstractLaser-induced graphene (LIG) decorated with metallic nanoparticles (MNP) offers a scalable route to high-performance carbon electrodes for energy storage and electrochemical sensing. This thesis investigates how monometallic (Ag, Pt) and bimetallic (Ag-Pt) nanoparticle decorations modify the capacitance origins and sensing performance of LIG, with emphasis on separating double-layer, pseudocapacitive, and quantum-capacitance contributions.<br/><br/>LIG electrodes were fabricated by laser processing of polymer precursors followed by controlled drop-casting of nanoparticle suspensions. Electrochemical evaluation employed cyclic voltammetry (CV), galvanostatic charge-discharge (GCD), linear polarization, and Dunn's method to deconvolute capacitive contributions. Selected systems were further analysed with a time-domain Randles-equivalent circuit as a substitute for direct Electrochemical Impedance Spectroscopy (EIS).<br/><br/>The two monometallic series show distinct loading optima, where Pt-LIG peaks at 10 µg mL⁻¹ (0.236 mF cm⁻²) and Ag-LIG at 14 µg mL⁻¹ (0.275 mF cm⁻²), with capacitance declining at 18 µg mL⁻¹ in both cases, attributed to nanoparticle aggregation. Bimetallic Ag-Pt-LIG samples, prepared at a matching 10 µg mL⁻¹ total loading across three Ag:Pt ratios (30:70, 50:50, 70:30), reach 1.158, 1.176 and 1.362 mF cm⁻² at 50 mV s⁻¹, approximately 4 to 5 times above the best monometallic electrode and 12 to 14 times above pristine LIG (0.100 mF cm⁻²), with the Ag-rich 70:30 ratio highest.<br/><br/>Dunn's-method decomposition gives surface-controlled fractions of 62 to 74% for the monometallic electrodes but only 21 to 59% for the bimetallic, indicating that the bimetallic synergy acts predominantly through diffusion-controlled pseudocapacitive channels rather than through double-layer charging.<br/><br/>In a sensing demonstration, NP-LIG electrodes were evaluated for capacitive, non-Faradaic detection of glucose over a 0 to 5 mM window in 1 M KCl. To the author's knowledge these are the only LIG-based glucose sensors operating in a capacitive readout regime.<br/><br/>This work contributes a systematic framework for attributing capacitance in NP-LIG hybrids to physical and electronic origins, comparative performance maps for Ag, Pt, and Ag-Pt systems, and practical guidelines for nanoparticle loading and deposition.
Degree
thesis:*- Name dc:type.qualificationname
- Ph.D.
- Level dc:type.qualificationlevel
- doctoral
- Grantor dc:publisher.institution
- University of Southampton
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Goh, Rou Xuan
- Advisors dc:contributor.advisor
-
- Ling, Ivan
- Pu, Suan Hui
- Chong, Harold
- Gan, Khong
- ORCID person:identifier.orcid
Rights
- Language dc:language
- English, eng
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.5258/SOTON/01/T096