Back to search

University of South Carolina

Volume Frequency Response Method for Determining Mass Transfer Mechanisms of O2 in Carbon Molecular Sieve 3K172

Abstract

dc:description.abstract

Carbon molecular sieves (CMS) have grown more desirable over the years as an adsorbent for industrial separation processes as CMS technology has advanced. CMS is commonly used in nitrogen inerting (i.e, oxygen removal from air), carbon dioxide removal from methane and oxygen purification. However, knowledge of the dynamic behavior of these gases on CMS is needed to design and operate efficient and effective separation processes. For this reason, the mass transfer resistances within the micropore at both low and high frequencies were characterized using frequency response, COMSOL Multiphysics modeling, and MATLAB optimization , because frequency response methods have demonstrated the ability to discriminate between limiting mass transfer mechanisms. This method is performed through a sinusoidal perturbation of volume, pressure, or concentration. Each method has unique advantages and disadvantages that need to be considered when determining the most appropriate for the adsorbate-adsorbent at hand. Due to the robustness and applicability of the volumetric frequency response system (VFRS), the current study focused on a previously constructed VSFR system to utilize the wide range of frequencies it handles, allowing for analysis of both slow and fast diffusing gases. Mass transfer mechanisms were identified utilizing the data obtained from this VFRS system and fitting it to a mathematical model for oxygen adsorbed by Shirasagi CMS 3K 172 from Takeda Chemicals at 750 torr at 20, 30, 40 and 50 °C and 100 and 200 torr at 25 °C. Three distinct zones were identified in which isothermal local equilibrium, micropore diffusion resistance, and mouth resistance dominated at low, intermediate and high frequencies, respectively. The model did not fit the phase lag data well at high frequencies but showed that an increase in temperature resulted in a decrease in the amplitude. Additionally, a parametric study was performed to demonstrate the effect of the heat transfer coefficient, heat of adsorption, adsorbent heat capacity, micropore diffusion, and mouth resistance on the adsorption kinetics. For the base case of oxygen at 760 torr and 20 °C, curves displayed a delayed drop in intensity as micropore diffusion limitations decreased. With an increase in mouth resistances, the slope of the intensity curves became steeper and the phase lag was shifted right. An increase in the heat capacity of the adsorbent caused a developing hill between 0.001 and 0.015 Hz, while an increase in the heat of adsorption shifted this hill downwards. An increase in the heat transfer coefficient caused an increase in the starting location of the intensity curve until equilibrium was reached and an increase in the heat transfer coefficient no longer had an effect. The heat transfer coefficient had no effect on phase lag amplitude.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering
Level thesis:degree_level
Open Access Thesis
Discipline thesis:degree_discipline
Chemical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smithson, Olivia
Contributors dc:contributor
  • James Ritter

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © 2020, Olivia Smithson

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarcommons.sc.edu/etd/6176

Chain of custody

source
Harvested from
University of South Carolina
Base URL
scholarcommons.sc.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Smithson, Olivia. Volume Frequency Response Method for Determining Mass Transfer Mechanisms of O2 in Carbon Molecular Sieve 3K172. Open Access Thesis thesis, https://scholarcommons.sc.edu/etd/6176