The Anaconda endovascular stent graft is a medical device designed to treat abdominal aortic aneurysms, composed of a nitinol wire structure and a fabric graft. The graft is required to undergo significant deformations before and after the implementation of the device. This thesis addresses the material characterization of thin nitinol wire taking advantage of the test methods already established for tensile and compressive behaviour, mainly focussing on the compressive response. The tensile behaviour here presented consists of a preliminary study of the localised deformation on nitinol wire. The mechanical characterization of the wire under compression starts with the implementation of digital image correlation (DIC) technique to measure the sample strainfield. The compressive test method was found to be unsuitable for compressive loading, where it was not possible to replicate the compressive tests, validate the DIC technique and does not hold the sample securely during the compressive test. This finding led to a complete change of the research goals and paved the way for the development of a test method for fine nitinol wire.A compressive test method is therefore proposed, which is shown to be valid under compressive loading and for obtaining the compressive material parameters as input to the numerical models. A parametric study was undertaken to understand the optimum ratio between the length and diameter of the sample. An attempt at using this method in a temperature-controlled environment is also presented. The application of the Auricchio constitutive model, implemented in the finite element software Abaqus, is considered. A comparison with an alternative non-commercial modelis also studied and reported along with some suggested improvements. This results in better prediction of the asymmetric behaviour of nitinol wire under compressive and tensile loading and is shown to be very promising in physically representing the bending behaviour of nitinol wire.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alves, Ana Sofia de Freitas
Advisors dc:contributor.advisor
  • Nash, David
  • Wheel, Marcus
Author Identifier dc:creator.authoridentifier
  • 201753937

Rights

Identifiers

dc:identifier.*
Identifier
T16303

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Alves, Ana Sofia de Freitas. Compressive mechanical behaviour of nitinol wires used in aortic stent grafts. doctoral-pg thesis, University of Strathclyde, 2022. https://stax.strath.ac.uk/concern/theses/0r967415x