Back to search

University of Strathclyde

Design of the rehabilitation glove : a soft wearable robotic device for repetitive hand rehabilitation therapy after a stroke

Abstract

dc:description.abstract

Stroke is the major cause of disability in the world today, and it touches up to 110 000 persons every year, only in UK, and up to 70% of the survivors of a stroke suffer from a moderate to severe disabilities in their upper-limb motion control, caused by damages in the cerebral motor areas. The recovery of post-stroke impairments is a hard and long treatment, because the patient has to recover his physical strength and functionalities, but he also needs his affected neural area to reorganise, in order to make significant progresses. The rehabilitation techniques are many and all of them have their pros and cons, but the physiotherapists have more and more troubles in handling the growing number of patients. Indeed the majority of the patients suffering from a stroke are aged over 60, and the global ageing of the population implies an increase of those disabled people, creating a work load and a cost too great for the conventional rehabilitation techniques. The aim of this project is to investigate upper-limb rehabilitation techniques and in particular robot-assisted rehabilitation, to find out what could solve this major issue. The existing devices will be reviewed and robotic rehabilitation devices pointed as a solution for future post stroke recovery therapy. The concept of a soft robotic glove for hand rehabilitation, coupling a flexible structure with a cable-driven actuation will then be developed, and the methods of design of a prototype will be followed. Both the mechanical coupling between the hand and the glove, using vacuum and suctions cups, and the control interface of the prototype will be developed. Finally, despite the only partial achievement of the prototype, future prospective and use for this device will be discussed, concluding on the promising results obtained.

Degree

thesis:*
Name dc:type.qualificationname
msc
Level dc:type.qualificationlevel
masters-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hosatte, Sylvain
Advisor dc:contributor.advisor
  • Yao, Wei
Author Identifier dc:creator.authoridentifier
  • 201491685

Rights

Identifiers

dc:identifier.*
Identifier
T14234

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Hosatte, Sylvain. Design of the rehabilitation glove : a soft wearable robotic device for repetitive hand rehabilitation therapy after a stroke. masters-pg thesis, University of Strathclyde, 2015. https://stax.strath.ac.uk/concern/theses/4m90dv58z