Back to search

University of Strathclyde

Assessment of coronal mechanical alignment with applied varus and valgus force through the range of flexion using non-invasive navigation

Abstract

dc:description.abstract

Osteoarthritis of the knee is a highly prevalent disease, with total knee arthroplasty (TKA) a proven means of alleviating symptoms. In image-free navigation, infra-red markers are attached to bony landmarks to provide kinematic data during the TKA procedure, with the aim of improving the precision of the implant placement. In non-invasive navigation, infra-red markers are attached to the skin surface; recent evidence suggests that this can give reliable measurements of lower limb mechanical alignment. The aim of this thesis was to evaluate the use of a non-invasive navigation system in the assessment of mechanical alignment with applied coronal force through the range of flexion. A previously validated non-invasive system (Physiopilot) was tested on 23 volunteers with healthy knees. 2 users performed 2 registrations of the software workflow on each participant's right and left knees. A force was manually applied to the end-point of varus and valgus knee laxity and the measured change in mechanical alignment was recorded. Force was applied with the knee positioned in increments of flexion from 0?-90?. In keeping with previous studies, satisfactory values of CR (Coefficient of Repeatability) of 1.55 and 1.33 were found for intra-observer repeatability in measurement of supine Mechanical Femoro-tibial Angle (MFTA) in extension, with a good inter-observer correlation of ICC (intraclass Correlation Coefficient) 0.72. However, when flexion was introduced, intra-observer and inter-observer reliability fell outwith acceptable limits. The trial therefore did not support the Physiopilot system as a measure of MFTA when flexion is introduced. It was felt that learning-curve, soft tissue artefacts and lack of force standardisation equipment may have accounted for significant levels of error, with further studies required to address these issues.

Degree

thesis:*
Name dc:type.qualificationname
mphil
Level dc:type.qualificationlevel
masters-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Henderson, Fraser
Author Identifier dc:creator.authoridentifier
  • 201353958

Rights

Identifiers

dc:identifier.*
Identifier
T14385

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Henderson, Fraser. Assessment of coronal mechanical alignment with applied varus and valgus force through the range of flexion using non-invasive navigation. masters-pg thesis, University of Strathclyde, 2016. https://stax.strath.ac.uk/concern/theses/5d86p028s