Back to search

University of Strathclyde

The design of a prosthetic foot unit for use in developing countries

Abstract

dc:description.abstract

The majority of prosthetic feet used in low-income countries suffer from a limited lifespan and limited durability. The aim of this project is to design a prosthetic foot suited to use in low-income countries that incorporates both durability and a high level of function. A review of the literature was carried out which included examining the form and function of the anatomical human foot and the existing prosthetic systems used in low-income countries as well as their limitations and successes. Also reviewed were methods of assessment of a prosthetic foot. A Product Design Specification (PDS) was created to outline the requirements of a prosthetic foot for use in a low-income country based on the information detailed in the literature review. An existing design of Strathclyde foot was tested statically according to the ISO 10328 standard. The design was modified to improve performance in identified areas followed by an evaluation of layered manufacturing processes. Having identified a potential manufacturing method for prototypes testing of materials was carried out to determine the suitability of these materials for testing. Samples of the new design were tested statically according to ISO 10328. The foot design was then further modified based on the test results, confirmed by the use of FEA at which point new prototypes were made and static testing was again carried out. A comparison of the Strathclyde foot to other feet used in low-income countries took place. The second redesign of the Strathclyde foot was assessed via force plate trials by a non-amputee subject wearing prosthetic stilts. Finally, conclusions were drawn with respect to achieving the PDS and further work was recommended to improve upon the existing design and reach the requirements of the PDS. Appendix A gives details of the roll-over shape testing carried out on a range of prosthetic feet while Appendix B details the FEA work carried out to support design modification.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Connolly, Philip Andrew
Advisors dc:contributor.advisor
  • Buis, Arjan
  • Solomonidis, Stephan
Author Identifier dc:creator.authoridentifier
  • 200882647

Rights

Identifiers

dc:identifier.*
Identifier
T14850

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Connolly, Philip Andrew. The design of a prosthetic foot unit for use in developing countries. doctoral-pg thesis, University of Strathclyde, 2018. https://stax.strath.ac.uk/concern/theses/8623hx82z