Back to search

University of Strathclyde

Non-invasive impedance monitoring of vascular cell growth on coronary stents

Abstract

dc:description.abstract

Coronary heart disease is the leading cause of death in developed countries. Implantation of a stent, by percutaneous coronary intervention, has emerged as a safe and widely used procedure to address this problem. However, a number of limitations remain with this technique, including potentially delayed healing of the artery endothelium. Recovery of the endothelium is a crucial factor in stent performance and has a strong influence on long term outcomes for the patient. Despite this, the precise mechanisms controlling re-endothelialisation are unclear and there are no means of non-invasively monitoring this process in vivo.Existing real time monitoring of impedance in cell cultures provides information related to cell activity, adherence and confluence. Therefore, collection of such information applied to coronary stents may be a first step towards a better understanding of their re-endothelialisation. This may also help in understanding the exact duration of antiplatelet therapy required and thus lower treatment costs and improve the long term patient outcomes.This project investigated the suitability of impedance spectroscopy as a real time technique for monitoring endothelial adhesion and growth on metal surfaces. Primary endothelial cells isolated from freshly excised porcine pulmonary artery were cultured successfully in vitro on a self-manufactured bio-sensor. The cells were also seeded onto a commercially available coronary stent and impedance measurements were made over time. Impedance measurements were performed at different stages of the cell growth in vitro.It was found that there was a relatively high degree of variability in the impedance measurements obtained. Further analysis revealed that this variability was related to variations in the manufacture process of the biosensors. In a small number of comparable experiments with low variability (n=3), the impedance values collected from the biosensor devices were found to be correlated with cell number. These encouraging findings warrant further investigation of the potential of impedance measurements for monitoring re-endothelialisation of coronary stents in real time.

Degree

thesis:*
Name dc:type.qualificationname
msc
Level dc:type.qualificationlevel
masters-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Van Eyck, Laurent

Rights

Identifiers

dc:identifier.*
Identifier
T13951

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Van Eyck, Laurent. Non-invasive impedance monitoring of vascular cell growth on coronary stents. masters-pg thesis, University of Strathclyde, 2014. https://stax.strath.ac.uk/concern/theses/dn39x1624