Back to search

University of Strathclyde

Patient-specific mathematical modelling if the hybrid procedure in the treatment of hypoplastic left heart syndrome

Abstract

dc:description.abstract

Hypoplastic Left Heart Syndrome (HLHS) is a rare congenital heart disease characterised by the underdevelopment of the left sided structures of the heart, compromising systemic blood supply. The Hybrid Procedure is a palliative repair that delays cardiopulmonary bypass surgery and allows the opportunity for left ventricular growth and biventricular repair. The ductus arteriosus is stented open via catheter, which allows the right ventricle to supply the systemic circulation. In order to balance the pulmonary-systemic flow ratio, branch pulmonary arterial bands are surgically placed. Currently, banding (and stent) dimensions are based on surgical experience, intuition and limited Doppler measurements. In mathematically modelling the Hybrid Procedure, it is possible to optimise the dimensions based on haemodynamic and ventricular data. These simulated results are often difficult and invasive to measure clinically. Due to the broad spectrum of abnormalities observed in HLHS, creating patient-specific models is an area for development. Therefore a thorough investigation of routinely collected clinical data was undertaken, assessing the potential collaboration between biomedical engineering and clinical protocols. A lumped circulation model of the post-Hybrid circulation was produced and clinically validated following novel investigation. An external band diameter of 3 mm was optimal, with 3.5 mm appropriate for larger patients. A patient-specific three-dimensional geometry was constructed and virtual surgery performed for a range of band diameters for steady state analysis. Boundary conditions were determined using matching patient-specific and literature data. This model was coupled to the lumped circulation model in a multiscale model. This highlighted the conflict of definition between internal and external diameter band dimensions. It was shown that the 2 mm internal band diameter was optimal. Regarding patient-specificity, it was demonstrated that current clinical practices are not conducive to mathematical modelling with many steps required in the processing of data. The quality of the data is suboptimal and will require multidisciplinary cooperation for future improvement. Due to the incompleteness of the data sets and the inconsistent data collection, full patient-specificity and predictive modelling was not achieved.

Degree

thesis:*
Name dc:type.qualificationname
engd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Young, Andrew G.

Rights

Identifiers

dc:identifier.*
Identifier
T13747

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Young, Andrew G.. Patient-specific mathematical modelling if the hybrid procedure in the treatment of hypoplastic left heart syndrome. doctoral-pg thesis, University of Strathclyde, 2014. https://stax.strath.ac.uk/concern/theses/g158bh328