An investigation to determine the capability of micro-scale zero-valent iron (?ZVI) in the remediation of Cr(VI)

Abstract

dc:description.abstract

Zero-valent iron (ZVI) has been developed as a remediation technology and used widely for the remediation of heavy metal contaminants, which are widely known to cause prolific health effects. In particular, nano-scale ZVI (nZVI) has been highly effective due to its high surface area, and thus high reactivity potential. However, nanotechnology is highly controversial with regards to its safety, and thus an alternative has been sought. Micro-scale ZVI (?ZVI) has a larger particle size than nZVI, and can therefore be used as an alternative. Within Glasgow, there is significant hexavalent chromium (Cr (VI)) contamination, and thus the use of ?ZVI in a permeable reactive barrier (PRB) is a potential solution for its remediation as opposed to current conventional granular ZVI PRBs. Through both batch and column experiments, it has been noted that ?ZVI has a good removal potential of Cr (VI). The batch experiments show an almost perfect linear correlation between percentage removal of Cr (VI) and mass of ?ZVI used during the experiments. An aqueous stock solution using potassium chromate (K2CrO4) was prepared at a concentration of 500 ?M. It can be determined that 50 g/L ?ZVI can be used to remediate 100% Cr (VI) from a concentration of 500 ?M in approximately 4 days. This correlation was not mimicked in the column experiments due to interaction from the sand used. The sand column displays significantly lower levels of Cr (VI) than initially introduced. This is due to the high silica content of the sand aiding in the removal of Cr (VI). However, despite the control sand column displaying significantly reduced Cr (VI) concentrations than the initial solution, the Cr (VI) levels in both ?ZVI columns have been reduced to below the detection limit, indicating that the ?ZVI does indeed successfully remove Cr (VI).

Degree

thesis:*
Name dc:type.qualificationname
mres
Level dc:type.qualificationlevel
masters-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Niven, Jennifer

Rights

Identifiers

dc:identifier.*
Identifier
T13171

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Niven, Jennifer. An investigation to determine the capability of micro-scale zero-valent iron (?ZVI) in the remediation of Cr(VI). masters-pg thesis, University of Strathclyde, 2012. https://stax.strath.ac.uk/concern/theses/k0698750g