Inter- and intra socket shape and volume consistency assessed using magnetic resonance imaging for hands-on and hands-off casting of amputee below knee sockets

Abstract

dc:description.abstract

Casting consistency has a great influence on the quality of socket fit. Investigations into the shape and volume of trans-tibial prosthetic sockets are complicated due to the difficulty in establishing an accurate reference grid. The use of Magnetic Resonance Imaging (MRI) presents a possible solution to this problem. However, the reliability of MRI in defining the stump/cast interface depends on the materials present not distorting the scanned image.Volume and shape consistency of two casting concepts namely Hands-on and Hands-off were explored using MRI. Prior to this the validity and repeatability of MRI when using common socket material were also examined.The results show that MRI is an accurate and repeatable method in dimensional measurement when using water doped with copper sulphate (CU). Controlled material tests were conducted and the experimental results indicate that the materials, silicone and wet Plaster of Paris (POP) doped with 1gr/l CU, do not distort or interfere with the scanned image. Moreover MRI accuracy was validated using controlled experiments using animal specimens with known volume and surface areas wrapped in POP and silicon liner. No significant errors were indicated.Residual limbs were cast of twelve persons with a unilateral below the knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of an amputee were registered to a common coordinate system using the tibia.The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between two methods. Additionally, inter and intra cast mean volume difference was not clinically significant based on the volume of one sock criteria. Furthermore neither Hands-off method nor Hands-on method results in a consistent residual limb shape as the coefficient of variation of intra cast shape differences were high. Although the resultant shape of the residual limb in Hands-off method was not repeatable, the intra cast shape difference was not clinically significant. However, the Hands-on shape difference is not clinically significant but equal to the maximum acceptable limit for a poor socket fit.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Safari, Mohammad Reza
Advisors dc:contributor.advisor
  • Buis, Arjan
  • Rowe, Philip

Rights

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.538838
T12728

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Safari, Mohammad Reza. Inter- and intra socket shape and volume consistency assessed using magnetic resonance imaging for hands-on and hands-off casting of amputee below knee sockets. doctoral-pg thesis, University of Strathclyde, 2010. https://stax.strath.ac.uk/concern/theses/r781wg067