Back to search

University of Strathclyde

High common-mode-noise-rejecting magnetic gradiometer for biomagnetic measurements

Abstract

dc:description.abstract

This project sits within the field of atomic magnetometry and biomagnetic sensing, with a specific focus on developing and characterising a high common-mode-noise-rejecting magneticgradiometer based on optically pumped magnetometers (OPMs). The work is motivated by the need to measure extremely weak magnetic signals, such as those produced by the heart and brain, which are often masked by environmental interference. Improving commonmode noise rejection is therefore essential for enabling reliable biomagnetic measurements in realistic laboratory, clinical, and potentially unshielded environments. Experimental data were collected using a two-channel Mx-type OPM gradiometer system.The setup included magnetically shielded vapour cells, Radio Frequency (RF) excitation coils, and VCSEL (Vertical-Cavity Surface-Emitting Laser)-based optical pumping. The system parameters were controlled through LabVIEW, with signals acquired via FPGA and exported for further analysis. MATLAB was used to process the data and generate plots showing amplitude, phase, relaxation rate, resonance frequency, and signal gradient as a function of VCSEL voltage. The results plot clear resonance behaviour linked to optical detuning across the caesium D1 transition. Peaks in amplitude, relaxation, and resonance frequency occur within a narrow voltage range, identifying the optimal operating region. Gradient analysis highlights the balance between signal strength and linewidth, revealing a voltage range where sensitivity is maximised. The experimental work primarily characterised the sensitivity of the system through the VCSEL voltage sweep, measuring amplitude, phase, relaxation, resonance frequency, and gradient as proxies for system performance. Direct quantitative measurement of the common-mode rejection ratio (CMRR) was not performed in this work. These findings provide insight into how optical pumping conditions influence magnetometer performance and stability. Understanding these relationships supports the optimisation of gradiometer operation and contributes toward the broader goal of improving noise rejection, sensitivity, and practical deployment of OPM-based systems for biomagnetic measurements.

Degree

thesis:*
Name dc:type.qualificationname
mres
Level dc:type.qualificationlevel
masters-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sahota, Goran Nath
Advisor dc:contributor.advisor
  • Ingleby, Stuart
Author Identifier dc:creator.authoridentifier
  • 202588448

Rights

Identifiers

dc:identifier.*
Identifier
T18096

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Sahota, Goran Nath. High common-mode-noise-rejecting magnetic gradiometer for biomagnetic measurements. masters-pg thesis, University of Strathclyde, 2026. https://stax.strath.ac.uk/concern/theses/st74cr030