Back to search

University of Strathclyde

Stereo vision technologies for retinal imaging

Abstract

dc:description.abstract

Early detection and treatment are crucial in limiting vision loss induced by primary open-angle glaucoma, a highly prevalent subtype of glaucoma, which is the second leading cause of blindness globally. Subjective assessment of the optic nerve head (ONH), which shows morphological change prior to the development of symptoms, is the cornerstone of early detection but suffers from poor intra- and inter-observer variability. Quantitative three-dimensional (3D) imaging technologies, which objectively quantify such change, have excellent repeatability and reproducibility, and have been shown to have higher diagnostic ability than general ophthalmologists. These could boost diagnostic ability in primary/community care if they were available at an affordable cost.In this work, two novel low-cost quantitative 3D imaging solutions, based on computer stereo vision, for 3D surface reconstruction of the ONH were developed. The first solution featured low-cost cameras and an indirect ophthalmoscopy lens fitted to a slit lamp. Later versions of the system also featured a projector, used to artificially add texture to the ONH to enhance stereo matching performance. Using eye phantoms, the systems were calibrated, and acquired images of ONH targets in the phantoms were processed using developed stereo vision pipelines to yield reconstructions. Such reconstructions were evaluated against ground truth data. Initial testing was also carried out with porcine eyes. Aiming for a miniaturised handheld system, the second solution featured two small cameras in an indirect ophthalmoscopy configuration, with a folded optical path provided by an appropriate set of mirrors, and a miniature projection system. This solution was tested in a simple eye phantom only.This work demonstrated ONH 3D reconstruction using both systems, with promising levels of precision and accuracy. Further work is needed, particularly with biological ONHs, to gauge their clinical potential. If sufficient, these systems have the potential to broaden access to 3D ONH imaging in future.

Degree

thesis:*
Name dc:type.qualificationname
engd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Coghill, Ian
Advisor dc:contributor.advisor
  • Giardini, Mario Ettore
Author Identifier dc:creator.authoridentifier
  • 201655713

Rights

Identifiers

dc:identifier.*
Identifier
T15885

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
related terms
citation