Optimisation of energy and brightness transformer stages in a plasma Wakefield accelerator

Abstract

dc:description.abstract

Capable of sustaining giga-volt-per-metre accelerating gradients, plasma accelerators are a promising technology that offer a path to compact machines for high-energy applications. In the case of a beam-driven plasma Wakefield accelerator (PWFA), energy is transferred from a driver particle beam to an existing bunch trailing in its wake; in this way, the plasma accelerator can be seen as an energy transformer. Alternatively a beam can also be formed directly inside the wake—a so-called plasma cathode. The quality of this new bunch can furthermore be higher than that of the incoming drive beam, where the plasma stage now acts as a brightness transformer.In the case of an energy transformer, this work focuses on an important quantity in plasma acceleration—the energy-transfer efficiency. Here, a new diagnostic was developed based on the light emitted from a beam-interacted plasma that can—in contrast to conventional dipole spectrometers—non-invasively measure the energy-transfer efficiency with longitudinal resolution on a shot-to-shot basis. After benchmarking this method with the spectrometer-based technique, local energy-transfer efficiencies of up to (58 ± 3)% were measured. Furthermore, the potential of this method in diagnosing transverse instabilities was investigated, with this diagnostic seen as being key to the monitoring and optimisation of future plasma accelerators.A PWFA-based plasma cathode stage was then also established and optimised, with the goal of demonstrating the brightness transformation of an input drive beam. Based on optically generated density downramp injection, bunches were internally injected with high reproducibility and accelerated with ? GVm?1 accelerating gradients. Thorough characterisation of these bunches yielded O(10pCMeV?1) peak spectral densities, percent level energy spreads and normalised emittances around an order of magnitude less than the drive beam. As a result, the 3D brightness of the injected bunches (i.e. brightness in the horizontal and spectral directions) was shown to be 4.8 times higher than that of the drive beam.Ultimately, both of the themes explored in this thesis are important if plasma accelerators are to meet the demands of future FEL light sources and linear colliders.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Boulton, Lewis
Advisors dc:contributor.advisor
  • Hidding, Bernhard
  • Sheng, Zheng-Ming
Author Identifier dc:creator.authoridentifier
  • 201877778

Rights

Identifiers

dc:identifier.*
Identifier
T16896

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Boulton, Lewis. Optimisation of energy and brightness transformer stages in a plasma Wakefield accelerator. doctoral-pg thesis, University of Strathclyde, 2024. https://stax.strath.ac.uk/concern/theses/xd07gt356