Back to search

Texas A&M University

Smart Urinary Catheter Bag for Multiplex Detection of Urine Parameters at the Point of Care

Abstract

dc:description.abstract

This research explores a comprehensive approach for the calibration and application of NT sensors to monitor pH and nitrite levels in artificial urine and investigate the survival and growth patterns of Escherichia coli (E. coli) in varying nutrient concentrations. The NT sensor calibration process used standard pH solutions (pH values 4, 7, and 10), standard nitrite solutions (10, 100, and 1000 ppm) and level sensor. The sensor was interfaced with an Arduino-based system to accurately measure and log data. The sensor was validated using serial dilutions and controlled testing environments. Sensitivity levels of +/- 1 for pH, +/- 5 ppm for nitrites and +/- 20 mL for level were ensured. The calibration procedure incorporated magnetic stirring and digital hot plate heating for consistent solution mixing. Tryptic soy broth was to used culture E. coli through serial dilutions and overnight incubation at 37 degrees C, before introducing it into the artificial urine test setup. The sensors were then used to measure changes in pH and nitrite concentrations as the bacteria grew. Data from the sensors were transmitted to mobile devices for real-time monitoring and analysis using Bluetooth and NFC communication modules. This novel approach provides an efficient and automated method to observe the dynamic interactions between bacteria and their environment in real-time. The findings from this research hold potential applications in biomedical engineering, particularly in developing automated diagnostic systems and advancing our understanding of microbial behavior in real-time urinary environments.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biomedical Engineering
Department thesis:degree_department
Biomedical Engineering
Grantor
Texas A&M University
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Korgaonkar, Jayesh Rajendra 1999-
Advisor dc:contributor.advisor
  • Ceylan Koydemir, Hatice
Committee members dc:contributor.committeemember
  • Godage, Isuru
  • Mabbott, Samuel
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Rights

Language dc:language.iso
English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1969.1/1594635

Chain of custody

source
Harvested from
Texas A&M University
Base URL
oaktrust.library.tamu.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Korgaonkar, Jayesh Rajendra 1999-. Smart Urinary Catheter Bag for Multiplex Detection of Urine Parameters at the Point of Care. Masters thesis, Texas A&M University, 2024. https://hdl.handle.net/1969.1/1594635