AN IN VITRO COMPARISON OF PIEZOELECTRIC AND ROTARY OSTEOTOMIES DURING LATERAL SINUS WALL SURGERY

Abstract

dc:description.abstract

Piezoelectric and high speed rotary instrumentation have proven to be viable methods of preparing osteotomies during lateral sinus wall surgery. Piezoelectric units have been suggested to have superior access and control as well as the ability to discern between soft and hard tissue. The major disadvantage of the piezoelectric technology is the reduced speed at which osteotomies are prepared. The purpose of this study was to evaluate the difference in operator perception, speed and membrane damage between the two modalities. Seven different operators prepared 4 osteotomies in 2 mm thick polyurethane sheets backed by 0.2 mm thick plastic wrap. The preparation speed and incidence of membrane damage were recorded after each osteotomy. The operator perception of each modality was recorded at the end of the preparations. Several questions were asked to evaluate the accuracy, visibility, vibration, comfort and ease of use of both modalities. Results showed that rotary instrumentation was 160% faster than piezo (p<0.001), but resulted in 370% more damage and 130% more perforations (p<0.01). Surveys of operator preference showed piezo units with higher scores for accuracy and visibility (p<0.05). This study showed that in vitro a piezo unit compared to a rotary unit results in less membrane perforation and damage, higher perception of accuracy and visibility, but longer osteotomy preparation time.

Degree

thesis:*
Department dc:contributor.department
Oral Biology
Grantor dc:publisher
Temple University. Libraries
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nicolucci, Jeff Duncan
Advisor dc:contributor.advisor
  • Suzuki, Jon, 1947-
Committee members dc:contributor.committeemember
  • Rams, Thomas E.
  • Brown-Joseph, Belinda
  • Boston, Daniel

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • IN COPYRIGHT- This Rights Statement can be used for an Item that is in copyright. Using this statement implies that the organization making this Item available has determined that the Item is in copyright and either is the rights-holder, has obtained permission from the rights-holder(s) to make their Work(s) available, or makes the Item available under an exception or limitation to copyright (including Fair Use) that entitles it to make the Item available.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Other
864885214

Chain of custody

source
Harvested from
Temple University
Base URL
scholarshare.temple.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nicolucci, Jeff Duncan. AN IN VITRO COMPARISON OF PIEZOELECTRIC AND ROTARY OSTEOTOMIES DURING LATERAL SINUS WALL SURGERY. Temple University. Libraries, 2011. https://hdl.handle.net/20.500.12613/2015