Texas State University
Online Monitoring of Bacteria and Bromate using Prototype Analyzers in a Pilot Direct Potable Reuse System
Abstract
dc:description.abstractAs global water scarcity becomes increasingly critical, direct potable reuse (DPR), where treated wastewater is directly recycled into drinking water without the use of an environmental buffer, offers a potential solution to augment drinking water supplies. Monitoring contaminants in these systems, including pathogenic microorganisms and regulated drinking water disinfection byproducts like bromate, can help ensure the safety and reliability of the treated water for human consumption. This thesis evaluates the performance of online bacteria and bromate analyzers within a pilot-scale DPR system installed and operated at the City of San Marcos Wastewater Treatment Plant, San Marcos, TX. The study aimed to monitor real-time changes in bacterial counts and bromate concentrations as the DPR system runs. While the bacteria counter is based on the measurement of autofluorescence of riboflavin and nicotinamide adenine dinucleotide in bacteria cells, the bromate analyzer utilizes the quenching effect of bromate ion on the fluorescence of trifluoperazine in acidic conditions. Experiments with the bacteria analyzer demonstrated its capability to detect fluctuations in bacterial levels between different treatment stages, offering insights into the efficiency of the ultrafiltration, reverse osmosis, and UV processes in the DPR system, in terms of bacterial removal. Throughout the experiments, the bacteria analyzer exhibited a high level of sensitivity in bacterial counts, both highlighting its technical capabilities and presenting challenges in achieving consistent measurements. The bacterial counts from the analyzer were compared with heterotrophic plate counts (HPC), which are a standard method of quantifying heterotrophic bacteria in water. The results showed a low correlation (R2 = 0.1089) between the analyzer and HPC tests. Experiments with the bromate analyzer monitored variations in bromate concentrations in response to changes in ozone dose in an ozone-biological activated carbon train, aiming to limit bromate concentrations to be under the United States Environmental Protection Agency’s (USEPA) maximum contaminant level (MCL) of 10 µg/L. The bromate analyzer ran for 72 hours in an online experiment, and its measurements were subsampled and compared with measurements from liquid chromatography with tandem mass spectrometry (LC/MS-MS). The results showed a moderate level of correlation (R2 = 0.4491) between the bromate concentrations measured by the analyzer and the ones measured with LC/MS-MS. The analyzer measured changes in bromate concentrations as ozone doses changed, and provided the information needed to adjust ozone doses to bring bromate levels below the USEPA MCL. This thesis research showcased both analyzers’ practical application by responding to operational changes in the DPR pilot and providing real-time feedback to inform decision making. However, it also highlighted the technological difficulties in online monitoring and provided insights into the technical advancements needed to improve these analyzers. These insights pave the way for further refinements to bring these analyzers to the point where they are fully functional and able to be seamlessly integrated into DPR facilities.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Engineering
- Department thesis:degree_department
- Engineering
- Grantor
- Texas State University
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Leontieff, Daniel A.
- Advisor dc:contributor.advisor
-
- Ikehata, Keisuke
- Committee members dc:contributor.committeemember
-
- Gutierrez, Felipe
- Fujio, Takahiro
Subjects
dc:subject × 2Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Leontieff, D. A. (2024). Online monitoring of bacteria and bromate using prototype analyzers in a pilot direct potable reuse system. [Master's thesis, Texas State University].