Back to search

Texas State University

In-Vitro Detection of tRNA Fragments (tRFs) Using an Inkjet-Printed Graphene Electrochemical Aptasensor

Abstract

dc:description.abstract

tRNA fragments (tRFs) presented in bodily fluids such as blood, urine, and saliva, can be used as non-invasive diagnostic biomarkers for a variety of diseases, such as disease progression and prognosis of cancers, neurological disorders (i.e., Alzheimer's disease), and viral infections (i.e., hepatitis B and C). Studying and detecting specific tRFs can help in the application of early disease detection, monitoring disease progression, and predicting treatment response. A novel, economical, portable, and disposable aptamer-based biosensor on an inkjet-printed graphene/Ag/AgCl electrode was developed for a POC diagnostic devices, in which RNA-aptamers for a specific tRF were immobilized to the working electrode. The 31-nt aptamer sequence, 5’-GCGGGAATACTTACCACTATACTACTTGGAC-3’ with 5'-Amino C6 modification. The graphene working (WE) and counter electrodes (CE) and silver-silver chloride reference electrode consisting of stable and uniform surface morphology tested by SEM imaging. An electrochemical system was developed that utilizes an aptamer-grafted 2.32 mm2 working graphene electrode, a 12 mm2 graphene counter electrode, and an Ag/AgCl reference electrode for the detection of target samples. To prevent any non-specific binding of target molecules on the surface of the WE, the electrode surface was modified to introduce specific binding sites for the target molecules. The WE surface was modified with a 10-minute treatment of oxygen plasma to enhance the carboxyl groups on the surface followed by the incubation under EDC-NHS solution for 35 minutes to bind amine groups on the functional groups. Additionally, blocking agents are used to prevent any non-specific bindings of other molecules on the surface of the working electrode. The sensor was analyzed in terms of the immobilization of aptamer and the detection of tRF using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) after the incubation period. The aptamer concentration was 10 mM for each experiment. The target DNA that was used was CTAGTGCGGGAATACTTACCACTATACTACAACGACC (XS_Asp31_R) with an orientation of 3’-5’ and the control DNA used with a sequence of CTAGTGCGGGAATACTTACCACTATACTACAACGACC (XS_Asp31_R) with an orientation of 5’-3’. The target DNA concentration was varied from 10 mM to 30 mM to gain an understanding of the sensor's sensitivity and limit of detection. This research contributes to the development of a highly accurate point-of-care tRF detection system that can be widely used for various diagnostic purposes.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Department thesis:degree_department
Engineering
Grantor
Texas State University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mannan, Musa Ibne
Advisor dc:contributor.advisor
  • Kim, Namwon
Committee members dc:contributor.committeemember
  • Kang, Hong-Gu
  • Chen, Maggie Yihong

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Mannan, M. I. (2023). In-vitro detection of tRNA fragments (tRFs) using an inkjet-printed graphene electrochemical aptasensor. [Master's thesis, Texas State University].

Chain of custody

source
Harvested from
Texas State University
Base URL
digital.library.txst.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Mannan, Musa Ibne. In-Vitro Detection of tRNA Fragments (tRFs) Using an Inkjet-Printed Graphene Electrochemical Aptasensor. Masters thesis, Texas State University, 2023. https://hdl.handle.net/10877/18968