dc:description.abstractContext: Exertional heat stroke (EHS) is a life-threatening condition that occurs when body temperature is greater than 40.5°C (105°F), and the patient displays central nervous system dysfunction. Cold water immersion (CWI) is the gold standard method of treating EHS. However, large water volumes used in CWI can create challenges (e.g., drainage, slipping) for medical staff in emergency rooms (ER) and ambulances. Medical professionals have recently noted that using only ice to cool EHS patients has shown favorable prognoses. The Polar Life Pod (PLP), a body bag like device, is a tool that can contain ice and water, but there is a lack of research on the use of just ice for cooling. We determined the cooling rates of 3 different ice masses and no water (9kg, 27kg, 53kg) in the PLP, and if they met the ‘acceptable’ (>0.08°C/min) and ‘ideal’ (>0.15°C/min) minimum cooling rate thresholds. Methods: Twelve subjects (8 males, 4 females) participated in 3 trial days, consisting of either 9kg, 27kg, or 53kg of nugget ice used for cooling. Subjects exercised within a hot room (heat chamber) set to ~40°C (~104°F) and ~40% humidity on a treadmill in a plastic rain poncho. Subjects walked for 3 minutes (3mph and 0% incline) followed by sprinting for 2 minutes at 90% of age-predicted maximum heart rate (Max Potential HR = 220-age * 0.9). They repeated intervals until core body temperature reached 39.75°C (~103.55°F). Subjects then entered the PLP and cooled with the designated amounts of ice across the three separate trials. Upon reaching rectal temperature (TREC) of 38.25°C (~100.85°F), subjects were removed from the PLP and recovered within the heat chamber for 15 minutes. Results: The highest cooling rates were displayed with larger ice masses (53kg) in the PLP. All ice masses met the ‘ideal’ threshold for cooling (9kg:0.15±0.05°C/min; 27kg:0.19±0.07°C/min; 53kg:0.27±0.10°C/min, P<0.001) with minimal water created from melting of the ice (9kg: 3.8±1.1L; 27kg: 5.3±2.1L; 53kg: 4.9±2.2L, P=0.07). Conclusion: All three ice masses (9kg, 27kg, 53kg) utilized in the PLP for cooling proved to sufficiently reduce TREC at ideal rates. Using just ice may be effective for reducing the challenges that are faced when using CWI in ambulance and hospital settings. Using just ice can also be effective in the event of patient emesis or incontinence.
Degree
thesis:*- Department dc:contributor.department
- Health and Human Performance
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Beck, Jessie
- Advisor dc:contributor.advisor
-
- Miller, Kevin
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Beck, J. (2025). Using ice packing and the polar life pod to treat hyperthermia. [Honors Capstone, Texas State University].