Back to search

Texas State University

Optimization of Molecular Buoys for Nucleic Acid Capture in Liquid Biopsy

Abstract

dc:description.abstract

Liquid biopsy for early cancer detection requires efficient nucleic acid extraction from 5–10mL of plasma, but current technologies like silica spin columns and magnetic bead systems cannot scale beyond 1–2mL without significant recovery losses. Molecular buoys are chitosan-functionalized hollow silica microspheres that capture nucleic acids electrostatically and passively float to the sample surface under their own buoyancy, requiring no centrifugation, magnetic fields, or laboratory instrumentation. Although previously validated for pathogen capture, the platform had never been systematically optimized for the performance parameters critical to clinical translation. This study conducted six experiments in pseudo wastewater to optimize three key parameters: chitosan functionalization concentration, microsphere-to-sample concentration, and sample volume scalability. Nucleic acid capture was quantified spectrophotometrically, and aptamer binding kinetics were characterized by fluorescence microscopy. All statistical analyses were performed using parametric and non-parametric tests selected through a diagnostic decision tree based on normality and variance homogeneity assessments. Chitosan-coated microspheres captured 4.0-fold more nucleic acid than unfunctionalized controls (19.23 vs. 4.86µgmg−1, p = 0.007). Per-bead efficiency peaked at 1mgmL−1 bead concentration and declined at higher loadings due to steric crowding. Systematic screening of ten chitosan concentrations (0.002–0.5%) identified 0.05% as the optimum, yielding 23.64µgmg−1; a 2.7-fold improvement over the prior protocol with the lowest coefficient of variation (7.5%). Total capture scaled linearly with sample volume from 1 to 10mL (Pearson r = 0.987), and the optimized protocol-maintained performance at a ten-fold scale-up (20.25µgmg−1, CV = 2.77%). The optimized protocol, 0.05% chitosan at 1mgmL−1 bead concentration provides a 2.7fold gain in capture efficiency using 50% fewer microspheres, with validated linear scalability across the volume range required for clinical ctDNA detection. These results establish the first systematically optimized operating protocol for the molecular buoy platform, pending validation in clinical plasma matrices.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biology
Department thesis:degree_department
Biology
Grantor
Texas State University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bhattarai, Niharika
Advisor dc:contributor.advisor
  • Weigum, Shannon
Committee members dc:contributor.committeemember
  • Du, Liqin
  • Vargas, Micaela

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Bhattarai, N. (2026). Optimization of molecular buoys for nucleic acid capture in liquid biopsy. [Master's thesis, Texas State University].

Chain of custody

source
Harvested from
Texas State University
Base URL
digital.library.txst.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Bhattarai, Niharika. Optimization of Molecular Buoys for Nucleic Acid Capture in Liquid Biopsy. Masters thesis, Texas State University, 2026. https://hdl.handle.net/10877/25174