Thermo-Economic Analysis of a PCM-Integrated Residential Building in Austin, Texas, USA using EnergyPlus
Abstract
dc:description.abstractResidential buildings in Texas account for nearly 40% of the state's total energy consumption, with space cooling representing the dominant end-use in the hot-humid climate of ASHRAE Climate Zone 2A. Despite growing interest in passive thermal energy storage technologies, comprehensive thermo-economic evaluations of Phase Change Material (PCM)integrated building envelopes under Texas-specific conditions remain insufficient in the literature. This study addressed that gap through a validated, simulation-based investigation of PCM integration in residential wall assemblies in Austin, Texas, using EnergyPlus v25.2. The simulation workflow was established by replicating two published international reference studies: a single-story rural residence in Anda City, northeast China (Li et al., 2021), and a two-story urban residence evaluated across four climates in Jordan and Romania (Jaradat et al., 2023). Replication of the China baseline model achieved agreement within 1.14%. For the Jordan study, close agreement was obtained for the Amman of 1.6% total energy deviation, and Oradea of 3.4% total energy deviation, while larger deviations for Irbid and Aqaba were attributed to undisclosed simulation parameters in the source study. Furthermore, PCM integration in the China case validated within a 0.63-3.63% deviation range across three placement configurations, confirming the accuracy of the EnergyPlus CondFD algorithm for PCM heat transfer modeling. A Texas-specific residential baseline model was developed in two geometric configurations, rectangular (aspect ratio 1.92:1) and square (aspect ratio 1.07:1), with identical total floor areas of 234.02 m² and conditioned floor area of 199.24 m², evaluated under four orientations. Preliminary results establish that: (1) south-facing orientation minimizes total Annual energy demand for both configurations; (2) the square geometry reduces total Annual energy consumption by approximately 4-8% compared to the rectangular form; (3) fiberglass insulation reduces heating energy by up to 75.76% and cooling energy by up to 61.79% compared to walls without insulation; and (4) increasing window-to-wall ratio from 10% to 50% raises Annual heating demand by 32.84% due to increased thermal transmittance of glazing. BioPCM, a bio-based organic phase change material encapsulated in commercially available sheet modules, was then integrated into the validated, insulated, south-facing square model at three thicknesses (e.g., 12.7 mm, 19.1 mm, and 25.4 mm) and four melting temperatures (e.g., 21°C, 23°C, 25°C, and 27°C) across three wall layer positions and a roof application. The 25°C melting temperature at 25.4 mm thickness, installed on the interior side of the external walls and roof (Case 1), achieved the largest combined heating and cooling energy reduction of 23.73% (1,048 kWh/year) compared to the CondFD-base reference case, which is 4417 kWh/year. This configuration was identified as the economically practical option, as dual-layer installation (Case 3) provided only 43 kWh/year of additional savings for an incremental cost of 14,947. Under a Texas comfort sensitivity analysis scenario (21.5°C heating / 22.5°C cooling) to maintain an indoor setpoint of 22°C, BioPCM23 outperformed BioPCM25, reducing Annual HVAC by 18.66% (1301 kWh/year) and Annual cost savings of 226 because its 23°C melting point aligned with the indoor operating range. A life-cycle cost analysis using Austin Energy electricity tariffs over 25 years at a 3% discount rate showed that simple payback periods ranged from 136 to 270 years at current BioPCM prices (48.44–107.64/m²), indicating that PCM integration using commercially available sheet modules is not yet economically viable for Texas residential construction under present material costs. The findings provide evidence-based design guidance and identify the cost reductions necessary for PCM adoption to become economically attractive in hot-humid residential markets.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Construction Management
- Department thesis:degree_department
- Engineering Technology
- Grantor
- Texas State University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gautam, Madhav
- Advisor dc:contributor.advisor
-
- Espinoza Chavez, Wilson
- Committee members dc:contributor.committeemember
-
- Debs, Luciana de Cresce El
- Martinez, Carlos Moro
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Gautam, M. (2026). Thermo-economic analysis of a PCM-integrated residential building in Austin, Texas USA using EnergyPlus. [Master's thesis, Texas State University].