Back to search

Texas State University

A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy

Abstract

dc:description.abstract

The following research is a feasibility trial for the development of a continuous glucose monitoring system using electrochemical impedance spectroscopy. Three separate experiments are conducted to determine the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, and a real time measuring trial of glucose sensing at low, medium, and high concentration levels over a period of fixed frequency and voltage excitation. The resultant data from each of the trials is modeled using electrical equivalent circuits and analyzed via Nyquist and Bode configurations to identify relevant data for each experiment. Results indicate that as electrode surface area increases, the impedimetric response decreases and sensitivity is increased. Deviations throughout the entire glucose range are detected as an inverse of the impedance in the cell due to the inverse relationship of glucose concentration and charge transfer resistance. The continuous monitoring of glucose is demonstrated by a rapid device response over two iterations of glucose concentration in ascending order. As concentration increases, resolution of the impedance signature is reduced suggesting the approach of a saturation set point.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Technology Management
Department thesis:degree_department
Engineering Technology
Grantor
Texas State University
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moore, Sean
Advisor dc:contributor.advisor
  • Song, In-Hyouk
Committee members dc:contributor.committeemember
  • Kim, Namwon
  • You, Byoung Hee

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Moore, S. (2016). A non-enzymatic continuous glucose monitoring system using electrochemical impedance spectroscopy. [Master's thesis, Texas State University].

Chain of custody

source
Harvested from
Texas State University
Base URL
digital.library.txst.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Moore, Sean. A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy. Masters thesis, Texas State University, 2016. https://hdl.handle.net/10877/6422