Back to search

The University of Texas at Austin

Amperometric DNA sensing using wired enzyme based electrodes

Abstract

dc:description.abstract

A water soluble copolymer of acrylamide and 4-vinylpyridine complexed with [Os(bpy)2Cl]+/2+ (bpy = 2,2’-bipyridine), was synthesized. An electrodeposition method of making redox polymer films on electrodes was developed. This method was also shown to be effective in incorporating enzymes and amine-terminated DNA sequences in the redox polymer film. A 38-base DNA sequence was detected at 20 pM concentration in 15-35 μL droplets by an electrochemical enzyme-amplified sandwich-type assay on a mass-manufacturable screen printed carbon electrode with a diameter of 3.5 mm. A DNA-capturing oligonucleotide was attached to the pre-deposited redox polymer film using the electrodeposition method. The electrode was exposed to the droplet containing the tested DNA sample, and was then treated with a droplet containing horseradish peroxidase-labeled detection sequence. Formation of the capture-target-detection sandwich brought the horseradish peroxidase-label of the detection sequence in electrical contact with the redox polymer, making the sandwich an electrocatalyst for the reduction of hydrogen peroxide to water at + 0.2 V (Ag/AgCl). The radial diffusion of electrons through the redox polymer film on the microelectrode allowed the electrodeposition of a thicker film of the redox polymer, an increase in the loading of the capture sequence, and increased the collection efficiency of the electron vacancies originating in the electroreduced H2O2. With a 10-μm diameter carbon fiber microelectrode, as few as 3000 copies of the 38-basse DNA sequence were detected at 0.5 fM concentration in a 10 μL sample. A biofuel cell operating at a power density of 50 μW cm–2 at 0.5 V under physiological conditions (air saturated, pH 7.4, 0.14 M NaCl, 37.5°C, 15 mM glucose) was developed. The cell had a glucose electro-oxidizing anode and an O2 electro-reducing cathode. The anode and the cathode were 7 μm diameter, 2 cm long carbon fibers, on which the catalytic enzyme-redox polymer adducts were cross-linked. When the miniature cell operated at 0.5 V, the power output dropped to about 60% of its initial value after 2 days of continuous operation at 37.5°C.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Chemical Engineering
Department thesis:degree_department
Chemical Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Yongchao
Advisor dc:contributor.advisor
  • Heller, Adam (Professor of chemical engineering)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OCLC
57192629
Identifier
b57476482
Dc Identifier Proquest
3122806

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation