The University of Texas at Austin
Refining materials testing methods for chemical and cementitious grouts
Abstract
dc:description.abstractGrouting is a well-established ground improvement technique that involves injecting fluid-like substances into soil or rock to enhance its properties. This process modifies the ground by filling voids and creating a stabilized mass with improved characteristics like permeability, bearing capacity, and settlement resistance. While various grout types exist, the primary categories are suspension (primarily cementitious) and chemical grouts. Cementitious grouts, made from cements like Portland or ultrafine, are widely used and offer cost-effectiveness but have limitations in versatility. Chemical grouts, including sodium silicates, acrylamides, and polyurethanes, provide greater adaptability but often come with higher costs. The successful application of grouting depends heavily on understanding the soil or rock characteristics and, more specifically, the grout's material properties. Essential properties like viscosity and gel time must be measured to optimize the grout mix design and ensure consistency. However, the lack of standardized testing methods or a lack of understanding in complex rheological behaviors in the industry hinders accurate comparisons and reliable quality control for both cementitious and chemical grouts. This study aims to address this gap. For chemical grouts, a crucial quality control metric is to accurately determine the gel time. Currently there are a variety of standardized and unstandardized procedures used to measure the gel time of chemical grouts, like the tilt cup test, viscosity tests relying on rotational viscometers, and the more advanced phase angle test in the Anton Paar Rheometer. This thesis aims to unveil the variability in the gel time measurements by comparing the recorded gel times from all methods using four different types of chemical grouts (methacrylic acrylate copolymers, acrylate monomer, acrylic resin, and sodium silicate). The results of this first study demonstrated a clear variability in the measured gel times from all tests for all materials except for one (acrylic resin). More specifically, the study showed that volume, evolution of temperature during the chemical reaction, and the cup geometry in the tilt cup test all played a role in impacting the measured gel times. Consequently, there is a clear need for standardizing the available methods to promote a clearer sense of quality control, reliability, and repeatability. The other study that was conducted within this thesis focused on understanding the bias in the Marsh Funnel viscosity measurements when testing non-Newtonian grout suspensions and learning how to accommodate for the bias. To measure and understand the bias, a series of modified Marsh Funnel tests were conducted on both Newtonian and non-Newtonian fluids. The results were then compared to a more accurate viscometer: the Fann Viscometer. Linear conversions and empirical equations were then relied on to convert the time-based Marsh Funnel viscosities into more realistic apparent viscosities and shear rates. Comparing the two tests demonstrated that Newtonian fluids can yield accurate converted viscosities, suspension grouts with a significant yield stress and a clear non-Newtonian behavior consistently underestimated the true viscosities, and the shear rates experienced at the tip of the funnel when testing all fluids are not representative of the true shear rates experienced in the field. However, relying on the last quarter of flow within the modified Marsh Funnel test significantly reduced the level of underestimation. By extending the Marsh Funnel test beyond the standard 946-mL of fluid helped further minimize the level of inaccuracy in the converted viscosities and the shear rates. In conclusion, the second study revealed and explained the bias associated with using the Marsh Funnel when testing non-Newtonian fluids, while providing a path forward towards developing a clear and simplistic method that can be used to readily determine the apparent viscosity of suspension grouts.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Discipline thesis:degree_discipline
- Geotechnical Engineering
- Department thesis:degree_department
- Civil, Architectural, and Environmental Engineering
- Grantor
- The University of Texas at Austin
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Govindan, Ashish Ajit
- Advisor dc:contributor.advisor
-
- El Mohtar, Chadi Said
- Committee member dc:contributor.committeemember
-
- Saracho, Alexandra Clara
Subjects
dc:subject × 6Rights
- Language dc:language.iso
- English
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/2152/129503