The University of Texas at Austin
Impacts of urbanization on water quality in the Boggy Creek Watershed in Austin, Texas
Abstract
dc:description.abstractPopulation growth and development in urban centers can negatively impact water quality through increased runoff, loss of riparian buffers, and wastewater leakage. Across the southwest U.S., water quality degradation in urbanized areas is exacerbated by increased water scarcity and drought intensity. Texas is one of the fastest growing states in the nation, with the capital city of Austin alone growing 19.8 % from 2010 to 2020. The impacts of this expansion are exacerbated in East Austin, which hosts the most environmentally degraded watersheds in the city. In the Boggy Creek watershed, the community organization PODER (People Organized in Defense of Earth and Her Resources) has identified the water resilience challenges of decreasing access, reduced recreational opportunities, and deteriorating water quality. Our objective is to better understand the processes and sources of water quality degradation in the creek. We apply elemental and isotope geochemistry along with bacterial analysis for sampling in 2024-2025. Stream water quality parameters vary spatially along Boggy Creek (pH = 7.1 - 11.2, total dissolved solids (TDS) = 240 - 910 ppm, Escherichia coli = <1.0E+00 - >2.4E+05 most probable number (MPN)/100 mL, ⁸⁷Sr/⁸⁶Sr = 0.70829 - 0.70968). These results can be accounted for by mixing between municipal water and natural stream water in proportions from 45% - 100% municipal water. Elevated proportion of anthropogenic indicators (e.g., Na and Cl⁻) as well as high NO₃⁻, E. coli, and ⁸⁷Sr/⁸⁶Sr values in the upstream sections of Boggy Creek are correlated with older infrastructure age and high population density. High stream discharge was observed under drought conditions at an upstream site that had been dry for the previous two months. Water quality parameters for the high discharge (pH = 9.2, TDS = 264 ppm, E. coli = <1.0E+00 MPN/100mL, ⁸⁷Sr/⁸⁶Sr = 0.70923) align closely with that of municipal supply water (pH = 9.4, TDS = 264 ppm, E. coli = <1.0E+00 MPN/100mL, ⁸⁷Sr/⁸⁶Sr = 0.70927). At a separate upstream site, a more than 450-fold increase in E. coli concentration was observed from April 2024 (5.2E+02 MPN/100mL) to May and June 2024 (>2.4E+04 MPN/100mL). After sharing these results with the city’s Department of Watershed Protection, a wastewater leak near the sampling site was identified and repaired, which led to a significant decrease in E. coli concentrations (1.5E+05 MPN/100mL in July to 2.9E+01 MPN/100mL in September 2024). Within a 2.5-km section of the creek that has been modified with concrete to prevent flooding, water quality consistently differs from the values observed in the unaltered areas of the creek. Water quality at the concrete-lined section is reflected by increased temperatures (4.0 °C - 8.0 °C higher) and pH levels (8.7 - 11.2), as well as decreased calcium (20 ppm - 64 ppm) and E. coli (<1.0E+00 - 1.1E+02 MPN/mL) concentrations. These results reveal multiple impacts of failing infrastructure and streambed alteration on water quality in urban watersheds, highlight the importance of temporal water quality monitoring, and demonstrate effective synergies of collaboration between stakeholders for environmental management.
Degree
thesis:*- Name thesis:degree_name
- Master of Geoscience
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Geological Sciences
- Department thesis:degree_department
- Earth and Planetary Sciences
- Grantor
- The University of Texas at Austin
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pagán González, Fernando Jesús
- Advisor dc:contributor.advisor
-
- Banner, Jay L.
- Committee members dc:contributor.committeemember
-
- Cardenas, Bayani M
- Kirisits, Mary Jo
- ORCID person:identifier.orcid
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- English
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/2152/136168