Back to search

The University of Texas at Austin

The effect of human-robot interface stiffness on kinematic tracking of the shoulder in the harmony exoskeleton

Abstract

dc:description.abstract

The development of rehabilitation exoskeletons for diseases such as stroke is a rapidly growing research field that boasts potential to restructure the rehabilitation process towards data driven approaches. Clinical results for rehabilitation studies often find that there are some statistical benefits of using robots over traditional physical therapy, which has encouraged further exploration. Mechanical design research related to exoskeletons often focuses on design features, such as the inclusion of passive joints or evaluating design efficiency by characterizing power transfer to the human body. However, little work has been done to validate the mechanical performance of exoskeletons for the shoulder girdle. While shoulder exoskeletons are often actuated through forces applied to the arm, knowledge on how different movements or attachment characteristics affect performance has not been quantified. Many factors of the exoskeleton's design affect the performance of the overall coupled system including: number of interaction ports, stiffness of attachment or cuff, inclusion of passive joints, attachment location, and attachment method. Since attachment stiffness is a design factor often considered in literature only for lower body exoskeletons, the goal of this thesis is to explore the fundamental effect of attachment stiffness on the Harmony upper body exoskeleton's ability to track the shoulder girdle's motion during various movement conditions. This knowledge is important since there is an intuitive tradeoff between improved tracking performance and decreased comfort for stiffer attachment interfaces due to higher pressure points at the human-robot attachment. In this study, a method is defined for experimentally obtaining sufficient information to characterize a shoulder exoskeleton's tracking performance based on attachment stiffness, scapulohumeral rhythm assistance, and wearer participation. A set of linear mixed-effects models obtained from empirical data show kinematic tracking results based on humerual cuff stiffness design choice. Force characteristics at the humeral attachment location are also modeled. Ultimately, the empirical models show that attachment stiffness to the humerus is not a statistically significant factor in contributing to shoulder tracking performance, and a models for the force characteristics at the humeral attachment show that attachment stiffness is a statistically significant factor. A softer attachment provides a simple design advantage by reducing the risk of pressure points while applying force to the human arm. Therefore, it is recommended that soft, less stiff cuffs are used to attach to the human arm when having an exoskeleton track shoulder movements due to its qualitative comfort benefits.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
Masters
Department thesis:degree_department
Mechanical Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Warburton, Kevin
Advisors dc:contributor.advisor
  • Sulzer, James S.
  • Deshpande, Ashish D.

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Warburton, Kevin. The effect of human-robot interface stiffness on kinematic tracking of the shoulder in the harmony exoskeleton. Masters thesis, The University of Texas at Austin, 2019. https://doi.org/10.26153/tsw/64008