Abstract

dc:description.abstract

Cardiac volume has been estimated using conductance technology that generates an instantaneous volume-dependant conductance signal. Unfortunately, the measured conductance is a combination of blood and myocardium, but only the blood conductance is desired. Hence, the instantaneous parallel myocardial contribution must be determined and removed from the total measured conductance signal in order to accurately measure cardiac volume. The currently adopted method assumes that the conductance-volume relationship is linear and the myocardial contribution to the total measured conductance is constant during a cardiac cycle. It also ignores either myocardial conductance or capacitance when estimating the myocardial contribution. This dissertation deals with these issues, and derives and validates a nonlinear conductance-to-volume conversion equation. It also proves that myocardial contribution varies during the cardiac cycle and develops a new method to calculate myocardial contribution using the fact that myocardium is both conductive and capacitive.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Department thesis:degree_department
Electrical and Computer Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wei, Chia-ling
Advisors dc:contributor.advisor
  • Pearce, John A., 1946-
  • Valvano, Jonathan W., 1953-

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OCLC
68817033
Identifier
b60840535
Dc Identifier Proquest
3145878

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Wei, Chia-ling. Improvements in the accuracy of estimation of left ventricular volume from measurements of complex admittance using a tetrapolar catheter. Doctoral thesis, The University of Texas at Austin, 2004. https://hdl.handle.net/2152/2177