Back to search

The University of Texas at Austin

Anchorage of grouted vertical duct connections for precast bent caps

Abstract

dc:description.abstract

In the last decade, the need to reduce traffic disruption at construction sites has led to innovations in bridge prefabrication. In Texas, most of these recent innovations have involved prefabrication of bent cap elements. Bent cap-tocolumn connections currently being used incorporate either corrugated galvanized steel or plastic ducts that are precast in the bent cap element to serve as sleeves to house connectors. Designers and contractors prefer this type of precast connection over other types because the volume of grout that is required to complete the capto-column connection is minimized. This research intends to reduce some of the uncertainties that currently surround the design of grouted vertical duct connections. The main test parameters that influence connection performance are identified. These parameters include bar coating, duct material, embedment depth, number of connectors, bar eccentricity, and transverse reinforcement. The experimental program examines the behavior and failure modes of grouted vertical duct connections. Results from thirty-two large-scale pullout tests are reported, and the effects of the studied parameters on connection behavior are evaluated. A simple phenomenological bond-slip model is presented that can be used to estimate the observed behavior. The development of the anchorage design provisions considers the stress in the connectors at service load levels. Design provisions are developed for connectors that experience: (1) compression or low tension, and (2) significant tension. Design provisions applicable to connectors that experience compression or low levels of tension are based on limiting serviceability stresses related to widespread splitting in the connection specimens. Connectors that experience significant tension and may be expected to yield are designed using anchorage provisions based on experimental average peak bond strengths. Observed pullout modes of failure are precluded by incorporating adequate levels of safety in the development of the design recommendations.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department thesis:degree_department
Civil, Architectural, and Environmental Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brenes, Francisco Javier
Advisors dc:contributor.advisor
  • Wood, Sharon L.
  • Kreger, Michael E.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OCLC
71314972
Identifier
b61207743

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Brenes, Francisco Javier. Anchorage of grouted vertical duct connections for precast bent caps. Doctoral thesis, The University of Texas at Austin, 2005. https://hdl.handle.net/2152/2396