Back to search

The University of Texas at Austin

Hydraulic characterization of structured packing via x-ray computed tomography

Abstract

dc:description.abstract

Unit operations such as distillation, absorption, and stripping rely on the contacting of vapor and liquid phases to achieve a desired chemical separation. Existing models used to predict the performance of packed columns are primarily empirical. Such models were developed using measurements of column bulk properties, such as overall liquid holdup, pressure drop, and inlet and outlet stream compositions. Variations in column behavior on a local scale are not captured by existing models, and constitute an area in which model improvement has a potentially large impact. Development of improved models will require non-traditional data for validation. X-ray computed tomography (CT) has been evaluated as one possible technique for measuring local flow behavior in packed columns. X-ray CT was used in this work to obtain images of an operating air-water contactor containing Mellapak 250Y stainless-steel structured packing. The image quality of two different X-ray scanner geometries, each with distinct temporal and spatial resolutions, was investigated. The void fraction and liquid holdup was calculated from CT images for a variety of liquid and vapor flow rates below the flood point. In general, average liquid holdup calculated from CT images was within 10 to 15% of holdup measured using traditional techniques. The axial variation in liquid holdup, particularly near packing element joints, was explored. Holdup was shown to vary throughout the column, and was greatest near the joint of adjacent packing elements. The region 0.25 to 0.4 inches above the interface exhibited holdup two to five times higher than the holdup measured in the packing element bulk. Three-dimensional images of the packed bed were acquired for static and dynamic conditions. The packing surface area, interfacial area between vapor and liquid, and the effective fractional area of a packed bed were calculated using three-dimensional reconstruction of two-dimensional CT images. Packing surface area was in good agreement with vendor-supplied values. Interfacial area measurements were compared with experimental data for vapor-liquid reactive area. Finally, both time variation of liquid flow and measurement noise during the course of data acquisition were quantified by analyzing the variation of X-ray transmission data.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Chemical Engineering
Department thesis:degree_department
Chemical Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Green, Christian Wayne
Advisors dc:contributor.advisor
  • Eldridge, R. Bruce
  • Allen, David T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OCLC
72582992
Identifier
b61292333

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Green, Christian Wayne. Hydraulic characterization of structured packing via x-ray computed tomography. Doctoral thesis, The University of Texas at Austin, 2006. https://hdl.handle.net/2152/2496