Cometabolism of trihalomethanes by nitrifying biofilters under drinking water treatment plant conditions

Abstract

dc:description.abstract

This research studied the feasibility of THM cometabolism in laboratory-scale biofilters under conditions that reflect drinking water treatment practice. Initially, batch kinetic studies were conducted to determine whether nitrifying bacteria could reliably cometabolize all four THMs at a sufficient rate to make the process attractive to utilities. The kinetic experiments showed that nitrifier communities likely to be seen in drinking water treatment facilities can degrade THMs at a sufficient rate by themselves, without seeding a pure culture. These results also indicated that temperature sensitivity and product toxicity could be concerns if THM cometabolism by nitrifying bacteria was implemented as a treatment option in treatment facilities. In particular, as bromine substitution increases, both THM degradation kinetics and product toxicity increase. A series of laboratory-scale biofilter experiments was conducted to investigate the feasibility of THM cometabolism in the envisioned process configuration. The operating conditions of the mixed culture biofilters scaled to typical full-scale rapid filtration operating conditions seen in drinking water treatment practice. Overall, the biofilter experiments suggest that, for a 2 mg N/L TOTNH3 (the sum of ammonia-nitrogen and ammonium-nitrogen) removal, total THM removals might initially approach 32-38% (25- 31 μg/L total THMs). This initial removal might decline to 11-12% (9-10 μg/L total THMs) over time as bacteria are selected from THM product toxicity. Even if this decreased performance occurs, the 11-12% removal is potentially attractive in drinking water treatment practice. The allowable influent monochloramine concentration resides between 1 mg/L to 2.5 mg/L as Cl2, with the use of 1 mg/L as Cl2 being conservative. A simple kinetic model for THM cometabolism was incorporated into AQUASIM to describe biofilter performance under conditions where by-product toxicity is not a concern. Overall, total THM removal of 9 to 54% was projected in the full-scale simulations, which illustrates the potential of THM cometabolism to have a significant impact on treated water quality for utilities where their water quality will likely see a benefit from the proposed process. Even though these removals are modest, drinking water treatment plants might only require removals in this range to maintain compliance with existing and future regulations.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department thesis:degree_department
Civil, Architectural, and Environmental Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wahman, David Gerard
Advisor dc:contributor.advisor
  • Speitel, Gerald E.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OCLC
166273479
Identifier
b6863934x

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Wahman, David Gerard. Cometabolism of trihalomethanes by nitrifying biofilters under drinking water treatment plant conditions. Doctoral thesis, The University of Texas at Austin, 2006. https://hdl.handle.net/2152/2946