Abstract

dc:description.abstract

Polymer transport with complex fluid rheology was implemented into an existing hydraulic fracturing simulator (CFRAC), and the implementation was extensively validated. Shear thinning viscosity was included for polymer fluid flow in both porous media and fractures. Shear thickening viscosity was implemented for flow in the matrix. Polymer injections were simulated to investigate the effect of polymer rheology, including both shear thinning and shear thickening behaviors, on polymer injectivity and on the possibility of induced hydraulic fracturing. The results indicated that shear thickening decreases injectivity and can induce initiation of hydraulic fractures. The hydraulic fractures substantially enhance injectivity, and eliminate the reduction in injectivity due to shear thickening. Pressure fall off tests were simulated to study the effect of polymer rheology on the identification of hydraulic fractures from the shut-in transient after shut-in. The results showed that standard methods from pressure transient analysis can be applied to diagnose the presence hydraulic fracturing by identifying a linear flow regime and fracture closure on a Bourdet derivative plot and a square root of time plot. It was found that these methods are effective regardless of shear thickening and shear thinning rheology. However, the results suggested that if the fracture is small and closes quickly, this could cause difficulty for the diagnosis.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Petroleum Engineering
Department thesis:degree_department
Petroleum and Geosystems Engineering
Grantor
The University of Texas at Austin
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ma, Yiwei, M.S.E.
Advisor dc:contributor.advisor
  • McClure, Mark W. (Mark William)
Committee member dc:contributor.committeemember
  • Balhoff, Matthew

Subjects

dc:subject × 2

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Ma, Yiwei, M.S.E.. Diagnosis of induced hydraulic fractures during polymer injection. Masters thesis, The University of Texas at Austin, 2015. https://doi.org/10.15781/T21K7W