Back to search

University of Texas at Austin

Effects of low-level silica fume replacement in ASTM C 1260 and ASTM C 227 mortar-bar testing

Abstract

dc:description.abstract

Replacement of a percentage of cement by supplementary cementing materials (SCM) can control deleterious alkali-silica reaction. Silica fume, a commonly used SCM, and can be used to mitigate alkali-silica reaction (ASR). As-produced, silica fume is very small (0.1 μm) and requires densification for economical distribution. The densification, transportation and storage process may produce larger agglomerated silica fume (up to mm in size). Recently there have been some discrepancies in data reported in the literature as to the effect of these silica fume agglomerates on alkali-silica reaction in laboratory and field experiments. These results led to an investigation of the root causes of these differences. This thesis presents finding from an extensive investigation into the effects of silica fume replacement on alkali-silica reaction. Three different silica fumes (two densified and one undensified) were tested in various combinations with four different aggregates (two non-reactive, one reactive, and one highly-reactive). Results from ASTM C 1260 and preliminary results from ASTM C 227 mortar bar expansion tests are presented. Scanning electron microscopy was used to analyze epoxy-impregnated 28-day mortar samples from the ASTM C 1260 tests. It was observed that one type of silica fume agglomerates was alkali-silica reactive, while another neither increased nor decreased alkali-silica expansion. The undensified silica fume effectively controlled alkali-silica expansion with all aggregates except the highly-reactive aggregate

Degree

thesis:*
Name thesis:degree_name
Master of Science in Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Civil Engineering
Department thesis:degree_department
Civil, Architectural, and Environmental Engineering
Grantor
University of Texas at Austin
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Maas, Andrew J.
Advisor dc:contributor.advisor
  • Juenger, Maria C. G.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Restricted
  • Copyright © is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
Language dc:language.iso
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Maas, Andrew J.. Effects of low-level silica fume replacement in ASTM C 1260 and ASTM C 227 mortar-bar testing. Masters thesis, University of Texas at Austin, 2004. https://doi.org/10.26153/tsw/12481