The University of Texas at Austin
Medication adherence among type 2 diabetes Texas Medicaid patients using basal insulin
Abstract
dc:description.abstractThis study assessed adherence to three types of basal insulins: neutral protamine Hagedorn (NPH), first and second generation long-acting insulins. This retrospective study used Texas Medicaid claims from 1/1/2014-6/30/2017 for patients 18-63 years, with ≥2 basal insulin claims. Patients also had: ≥1 claim for an oral hypoglycemic agent (OHA) or a glucagon-like peptide-1 receptor agonist (GLP-1 RA) 6-months pre-index, no claim for premixed insulin or basal insulin different from the index insulin 12-months post-index, and continuous enrollment. The index date was the date of the first basal insulin claim without a claim 6-months prior. Switchers were additionally required to have ≥2 pre-index claims for a basal insulin. The dependent variable was 12-month adherence to index insulin, using both mean and dichotomized (0.8 threshold) medication possession ratio (MPR) and adjusted MPR (aMPR). Bivariate and multivariate analyses were conducted. A total of 5,034 patients were included, the majority being between 40-63 years (85.5%) and female (65.9%). While only 28.2% of patients had MPR ≥ 0.8, 60.0% had aMPR ≥ 0.8. After controlling for covariates, compared to second generation long-acting insulin, there was a significantly lower odds of adherence (using MPR) to NPH [odds ratio (OR)=0.590, 95% confidence interval (CI)=0.372-0.935] and first generation long-acting insulin (OR=0.762, CI=0.589-0.985), whereas there was no difference in adherence (using aMPR). Other factors independently associated with better adherence irrespective of the measurement used (MPR vs. aMPR) included: older age, pre-index basal insulin use and better OHA adherence, more unique baseline medications, post-index fewer unique OHAs, bolus insulin use, and GLP-1 RA use. Vial delivery was associated with higher odds of adherence only when using MPR ≥ 0.8. Switchers included 218 patients switching to a longer-acting insulin and 588 switchers within first generation long-acting insulin. Adherence improved significantly after switching except for the aMPR-based adherence in switchers to a longer-acting insulin. Inconsistent results from MPR and aMPR and a lack of robustness of aMPR to sensitivity analyses suggested reliability issues with the measures. Comparing adherence using aMPR requires similar baseline characteristics at minimum. Future development of a reliable insulin adherence measure is needed
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Pharmaceutical Sciences
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Pharmaceutical Sciences
- Department thesis:degree_department
- Pharmaceutical Sciences
- Grantor
- The University of Texas at Austin
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Hanxi, M.S. in Pharmaceutical Sciences
- Advisors dc:contributor.advisor
-
- Barner, Jamie C.
- Moczygemba, Leticia R.
- ORCID person:identifier.orcid
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/2152/87202