Back to search

The University of Texas at Austin

Validity of digital thermal monitoring techniques to assess vascular reactivity following finger and brachial occlusion

Abstract

dc:description.abstract

Digital thermal monitoring (DTM) using the VENDYS-II device is an alternative, fully automated and noninvasive methodology to evaluate endothelial function using temperature change on finger as a surrogate measure of the magnitude of vascular reactivity index (VRI). Due to the simplicity, it could provide a more feasible technique to assess vascular endothelial function in the clinical setting. A most recent modification to the technique includes the application of occlusion cuff at the base of a finger. Therefore, the purpose of this study is to assess the validity of the VENDYS-II device compared with the standard flow-mediated dilation (FMD) protocol. Thirty-eight (22 males; 38±15 years) participants varying widely in age, health status, ethnicity, and socioeconomic status were studied. Occlusion cuff was placed over the right antecubital fossa or at the base of the right index finger. Temperature monitors were placed on bilateral index fingers to assess change in temperature throughout 5-minute occlusion and recovery phases. FMD was obtained simultaneously using high-resolution ultrasound. Shear rate total area under the curve (SR [subscript AUC]) was calculated for 180 cardiac cycles following cuff release. Mean brachial artery FMD was 7.5±2.2% and mean SR [subscript AUC] was 43,924±10,256. SR [subscript AUC] was significantly correlated with VRI obtained from brachial occlusion (r=0.34; p<0.05), but more strongly correlated with finger occlusion VRI (r=0.43; p<0.05) (Figure 1). Inversely, brachial FMD was more strongly correlated with brachial occlusion VRI (r=0.69; p<0.05), than finger occlusion VRI (r=0.53; p<0.05). VRI values obtained with the finger occlusion (1.58±0.29 AU) were not significantly different from VRI measured with the brachial artery occlusion (1.55±0.26 AU) (p=0.47), and both VRI values were moderately correlated with each other (r=0.25; p=0.47) Therefore, finger-based VRI may be a valid and novel alternative measure of endothelial function that is more suitable than the standard FMD or hyperemic shear rate for the assessment of endothelial function in the routine clinical setting.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Kinesiology
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Kinesiology
Department thesis:degree_department
Kinesiology and Health Education
Grantor
The University of Texas at Austin
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Heath, Melanie Ann
Advisor dc:contributor.advisor
  • Tanaka, Hirofumi, Ph. D.
ORCID person:identifier.orcid

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Texas
Base URL
repositories.lib.utexas.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Heath, Melanie Ann. Validity of digital thermal monitoring techniques to assess vascular reactivity following finger and brachial occlusion. Masters thesis, The University of Texas at Austin, 2020. https://doi.org/10.26153/tsw/14276