Abstract
dc:description.abstractThis dissertation focuses on the challenges faced by distance relays and their supervising elements, including directional, phase-selection, and loss-of-voltage (LOV) elements, in the systems with inverter-based resources (IBRs). A comprehensive dual current control scheme is proposed for IBRs during the low-voltage ride-through (LVRT) mode to address the challenges. This method addresses the shortcomings of existing solutions and enables correct operation of distance, directional, and phase-selection elements during all types of faults. The proposed method controls the IBR to operate as a voltage source behind a virtual impedance in the positive-sequence circuit and a single inductive virtual impedance in the negative-sequence circuit, thereby emulating the phase angles of an SG's fault current. The proposed method also maximizes the active and reactive current generation of the IBR during faults and emulates the relative incremental sequence current magnitudes of an SG. It is unveiled, for the first time, in this dissertation that IBRs can jeopardize the security of the LOV detection element, which is another supervising element for distance relays. A new LOV detection method is proposed to address this problem. The proposed solution centers around the fault current signature of IBRs and performs superior to the existing LOV detection elements. This method operates reliably regardless of the type of generation units in the system and is sufficiently fast to prevent relay misoperation during LOV conditions. The impact of different implementations of distance element on protection of systems with IBRs is also investigated in this dissertation. The focus is on the relays implemented using the phase comparators and the reactance method. It is unveiled, for the first time, that the ground and phase elements of a distance relay that uses these methods are prone to under-/over-reach in the systems with IBRs. A detailed analysis on the root causes of the problems as well as the measures to alleviate them is provided. Besides, it is shown that IBRs can adversely impact the operation of not only the distance relay that protects their tie-line but also the relays of the neighboring lines. The above studies are all supported by hardware-in-the-loop testing of commercial relays.
Degree
thesis:*- Department dc:contributor.department
- Electrical and Computer Engineering
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Banaiemoqadamfariman, Amin
- Advisors dc:contributor.advisor
-
- Hooshyar, Ali
- Iravani, Reza
Subjects
dc:subject × 6Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/128355