University of Toronto
Evaluation of MRI Methods for Ventricular Radio-Frequency Ablation Planning in Patients with Implantable Cardioverter-Defibrillators
Abstract
dc:description.abstractCurrent clinical guidance for primary and secondary prevention of sudden cardiac death is the administration of an implantable cardioverter defibrillator (ICD). ICDs stop acute sudden cardiac death via shock delivery, but often reduce patient quality of life due to frequent or improper shocks arising from cardiac arrhythmias. Radio-frequency catheter ablation is a curative treatment for cardiac arrhythmias that promises improved quality of life and reduction of improper ICD shocks. However, 35% of patients develop recurrent arrhythmias after an acutely successful catheter ablation procedure, motivating the development of novel imaging methods to determine ablation targets that terminate physiological circuits. Prior MRI studies have demonstrated the potential for robust catheter ablation planning using MRI-derived cardiac function, fibrosis, and parametric mapping data, with the clinical endpoints being freedom from ICD shocks and event-free survival. However, prior ICD implantation is often an exclusion criteria for MRI studies due to prior safety and image quality concerns. The overarching goal of my thesis research is to conduct experiments that evaluate current MRI-based methods for the purpose of catheter ablation procedural planning in patients with ICDs.In my first project, accuracy and interobserver variability of gradient-echo cine are evaluated in healthy volunteers with taped ICDs and patients with implanted ICDs, finding reduced image quality and broader interobserver variability than conventional cine. In my second project, substrate accuracy of wideband motion-corrected late gadolinium enhancement (LGE) imaging is evaluated in a cohort of pigs with taped ICDs and compared to conventional LGE without an ICD present. Wideband motion-corrected LGE found an increase in heterogeneous tissue corridors compared to conventional LGE imaging, which were not present in reference electrophysiological analysis. Towards improving specificity of MRI-based substrate analysis with ICDs, my third project investigates the use of wideband motion-corrected T1 mapping with automated cluster-based analysis to reproducibly segment dense and heterogeneous fibrosis. Automated cluster analysis was found to be not significantly different than manual analysis on the same mapping data, and segmented scar volumes from T1 mapping data were not significantly different than those calculated from reference LGE scans without ICDs. In summary, my thesis contributes to the unmet need for robust and reliable imaging in patients with ICDs for catheter ablation procedure planning, demonstrating the performance of current sequences in clinical and preclinical environments.
Degree
thesis:*- Department dc:contributor.department
- Medical Biophysics
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sheagren, Calder David
- Advisor dc:contributor.advisor
-
- Wright, Graham A
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/150201