University of Toronto
Development of a Knowledge-based Planning Pipeline for Gamma Knife Radiosurgery
Abstract
dc:description.abstractGamma Knife (GK) radiosurgery is a form of radiation treatment that utilizes narrowradiation beams to precisely treat abnormalities within the brain. Treatment planning for GK is traditionally performed using either forward planning, where planners manually configure shots to create a desired dose distribution, or inverse planning, where dose distributions are optimized based on multiple clinical objectives. However, both approaches are limited by their reliance on planner experience, in addition to several other drawbacks. To improve upon the current GK treatment planning process, a knowledge-based planning (KBP) pipeline was developed. This research was conducted in three stages: 1. Developing a novel 3D dose prediction methodology for GK. Machine learning methods are an integral part of most processes that generate personalized plans via KBP. The dose prediction model uses previous plans to learn the relationship between delineated medical images and dose to predict patient-specific dose distributions. It forms the first stage of the overall GK KBP pipeline. 2. Implementing an inverse optimization and inverse planning model. An inverse optimization model is first solved to estimate the objective function weights for the corresponding inverse planning model which would make the predicted dose optimal. These weights were then used to re-solve the inverse planning problem, generating a corresponding treatment plan that aligns with the initial predicted dose. This process serves as the second stage of the overall GK KBP pipeline. 3. Selecting appropriate isocenters using optimization. Isocenter placement has a significant impact on dose conformity and plan quality. To enhance plans generated using the KBP pipeline and reduce the need for manual intervention, the inverse optimization model and inverse planning model were extended to include optimization of isocenter locations, selected from a candidate set. The resulting KBP pipeline streamlines the GK planning process and minimizes the dependence on planner experience. It is capable of producing high quality treatment plans similar to or superior than their clinical counterparts.
Degree
thesis:*- Department dc:contributor.department
- Mechanical and Industrial Engineering
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Binghao
- Advisors dc:contributor.advisor
-
- Chan, Timothy C.Y
- Ruschin, Mark
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/150464