Back to search

University of Toronto

Asssessment of Tissue Viability in Acute Thermal Injuries Using Near Infrared Point Spectroscopy

Abstract

dc:description.abstract

Introduction: Currently, there are no objective techniques to assess burn depth. An early assessment of burn depth would enable accurate management decisions, which would improve patient outcomes. Near infrared (NIR) technology has shown promise as a non-invasive monitor of oxygenation and perfusion, and its potential to assess the depth of burn injuries has been investigated clinically over the past five years. The purpose of the thesis was to determine the capacity of NIR technology to differentiate acute thermal injuries. Methods: Burn sites (n=5) and control sites (n=5) were created on the dorsum of sixteen animals with brass rods held at constant pressure and heated to 100°C and 37.5°C respectively. NIR data was collected from the burns and control sites pre-burn, immediately post-burn, and 1, 12, 24, 36, 48 and 96 hours after the burn injury. Biopsies of the burn and control sites were acquired at each time point and used to confirm the depth of injury. NIR data was processed for the content of water, oxy-, deoxy- and methemoglobin. Results: Oxyhemoglobin and total hemoglobin decreased as burn depth increased. The proportion of oxy- and deoxyhemoglobin to total hemoglobin showed that the ratio of oxy- to deoxyhemoglobin decreased as burn injury increased. Methemoglobin levels as a ratio of total hemoglobin also showed that as the severity of injury increased the proportion of methemoglobin also increased. Finally, superficial partial thickness injuries (3 s and 12 s) showed early peak levels of water, which rapidly declined towards baseline. The deep partial thickness injuries (20 s and 30 s) do not experience peak levels and retain water over the course of the experiment. The full thickness injuries water levels remain close or below baseline levels throughout the experiment. Conclusion: NIR spectroscopy could distinguish burn depth using water, oxy-, met- and total hemoglobin as separate entities. The presence of methemoglobin in the burn wounds is a novel finding that has not been described previously in burn literature.

Degree

thesis:*
Department dc:contributor.department
Medical Science
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cross, Karen Michelle
Advisor dc:contributor.advisor
  • Fish, Joel Steven

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 2.5 Canada
Language dc:language.iso
en_ca

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/24731

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Cross, Karen Michelle. Asssessment of Tissue Viability in Acute Thermal Injuries Using Near Infrared Point Spectroscopy. 2010. https://hdl.handle.net/1807/24731