Back to search

University of Toronto

Noninvasive Source Localization of Extended Cortical Sources: Electroencephalographic and Magnetoencephalographic Source Imaging of Human K-complexes and Temporal Lobe Spikes

Abstract

dc:description.abstract

Electroencephalographic source imaging (ESI) and magnetoencephalographic source imaging (MSI) are used to identify brain regions responsible for generating the electromagnetic fields recorded outside the head using electroencephalography (EEG) and magnetoencephalography (MEG). However, as applied to the extended cortical sources underlying the high amplitude EEG and MEG potentials characteristic of human sleep and epilepsy, few studies have directly examined: (a) the reliability of ESI and MSI techniques and (b) the physiologic validity of ESI and MSI localization. This thesis examines the validity and reliability of current generation ESI and MSI as applied to these extended cortical sources.In a first study the intracranial localization of the largest potential in the normal human EEG, the sleep K-complex, was determined using stereoelectroencephalography (simultaneous scalp and intracranial EEG). The cortical field thus identified was chosen for further study as representative of a large superficial bilateral extended source.In a second study the intracranial localizations of interictal spike foci in patients with temporal lobe epilepsy were determined using stereoelectroencephalography. The anterolateral temporal neocortical field of the classical anterior temporal spike focus was chosen for further study as representative of a smaller, unilateral extended source.In a third study ESI and MSI were used to model the K-complex, and results compared to the true intracranial source. Results were reliable in terms of consistency from one K-complex to the next, however, solutions were falsely localized deep to the superficial cortical source. Distributed source modeling was not better than dipole mapping in this regard.In a fourth and fifth study ESI and MSI were used to model the anterior temporal spike field, and results compared to the true intracranial source. Reliability of ESI performed on single spikes was low, but valid localizations were consistently achieved with ESI performed on averages of topographically identical spikes. This was true for both dipole mapping and distributed source modeling. MSI localizational validity showed an expected dependence on source orientation and a similar improvement in reliability when performed on averaged spikes. Minimization of physiologic noise through signal averaging is important to maximize reliability and validity when modeling extended cortical sources of this size.

Degree

thesis:*
Department dc:contributor.department
Medical Science
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wennberg, Richard Arnold
Advisor dc:contributor.advisor
  • Douglas, Cheyne

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/68393

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Wennberg, Richard Arnold. Noninvasive Source Localization of Extended Cortical Sources: Electroencephalographic and Magnetoencephalographic Source Imaging of Human K-complexes and Temporal Lobe Spikes. 2014. https://hdl.handle.net/1807/68393