Back to search

University of Toronto

Lanthanide-containing Microgels Intended for Bead-Based Bioassays by Mass Cytometry

Abstract

dc:description.abstract

This thesis describes the synthesis and characterization of functional polyelectrolyte copolymer microgels intended for bioassays based upon mass cytometry. The microgels are based upon copolymers of N-isopropylacrylamide (NIPAm), N-vinylcaprolactam (VCL) and methacrylic acid (MAA), crosslinked with methlene-bis-acrylamide, poly(NIPAm/VCL/MAA). The microgels were loaded with Ln(III) ions, which were then converted in situ to LnF3 or LnPO4 nanoparticles (NPs). Very specific conditions were required for confining the NPs to the core of the microgels. I used mass cytometry to measure the number and the particle-to-particle variation of Ln ions per microgel. By controlling the amount of LnCl3 added to the neutralized microgels, we could vary the content of individual microgels from ca. 106 to 107 Ln atoms, either in the form of Ln3+ ions or Ln NPs. Leaching profiles of Ln ions from the Ln-containing microgels were measured by traditional ICP-MS. Under neutral or basic conditions, the leakage of Ln ions into the aqueous medium was not significant. In acidic buffer solutions, however, the leakage of metal from Ln3+ ion-containing microgels was prominent. On subsequent exposures to buffers, the microgels underwent continuous loss of metals. For LnF3-containing microgels, there was much smaller extent of metal leakage and very small of continuous loss of metal upon subsequent exposures to buffers. For LnPO4-containing microgels, there was very little detectable leakage of metals to the acidic buffers. In order to test the use of Ln nanoparticle as reagents of enhanced sensitivity in mass cytometry, we employed TmF3 encoded microgels as model cells. In one sample, Tm-encoded poly(NIPAm/VCL/MAA) microgels were coated with streptavidin (SAv) and used as model biomarkers, in quantitative mass cytometric bioassays. The sensitivity of different reagents (including a biotinylated metal cheating polymer, containing 50 Tb3+ ions per probe and a biotinylated NaHoF4 NP, containing 15,000 Ho atoms per probe) was examined for detecting and quantifying the number of SAv per microgel by mass cytometry. By using the Bi-PAsp(Tb)50 probes, a biomarker level at ~104 per cell was detected. By using the Bi-NaHoF4 NP probes, a biomarker level as low as ~102 per cell was quantified.

Degree

thesis:*
Department dc:contributor.department
Chemistry
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lin, Wanjuan
Advisor dc:contributor.advisor
  • Winnik, Mitchell

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 2.5 Canada
Language dc:language.iso
en_ca

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1807/68898

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lin, Wanjuan. Lanthanide-containing Microgels Intended for Bead-Based Bioassays by Mass Cytometry. 2013. http://hdl.handle.net/1807/68898