Abstract
dc:description.abstractThis study examines potential methods of achieving a reduction in X-ray radiation dose of Computer Tomography (CT) without significantly degrading the quality of the CT images. Assuming that the effective X-ray dose in CT is proportional to the product of the exposure area, the number of projections and the dose for each projection, four approaches are proposed to lower the radiation dose. Each of the proposed approaches controls one of these factors. Increasing the slice thickness increases the number of detected X-ray photons, thereby reducing the image noise. However, it also reduces the detectability and measurement accuracy of the small structures. An optimum slice thickness/overlap for low dose thoracic-CT images is proposed to compromise between the detectability and characterization accuracy of small pulmonary nodules.Compressed Sensing (CS) based CT reconstruction methods have shown significant potential for low dose CT imaging by reducing the number of projections. The connection between the statistical iterative CT reconstruction and compressed sensing is explored, based on maximum a posteriori formulation of CT reconstruction. It is shown that this formulation can be transformed into a weighted CS problem, the weights of which are direct consequences of the geometry and the CT statistics. A computationally efficient solution is proposed, enabling lower dose CT scans, while substantially reducing the computational load in comparison to conventional CS-based CT reconstruction methods.An iterative denoising algorithm is proposed to improve the CNR of the low dose CT images. To achieve this goal, a noise confidence region evaluation algorithm is proposed to adaptively update the regularization parameters, by validating the statistical properties of the denoised images at the end of each iteration. The algorithm stops when the statistical properties of the denoising residual resemble those of the considered noise. Finally, an innovative combination of a newly developed accelerated wavelet inverse Radon transform and non-convex CS formulation is proposed to recover the wavelet subbands of CT images from a reduced number of locally scanned projections. The proposed method reduces the radiation dose by simultaneous reduction of the number of projections and the area of exposure.
Degree
thesis:*- Department dc:contributor.department
- Biomedical Engineering
- Year dc:date.issued
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hashemi Amroabadi, Sayedmasoud
- Advisors dc:contributor.advisor
-
- Cobbold, Richard S.C.
- Paul, Narinder S
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/69275