dc:description.abstract

The primary method for treating acute ischemic stroke - the administration of thrombolytics - is associated with a relatively low efficacy and a large number of patients are contraindicated against the use of the drug. This research was motivated by the need to develop a new treatment modality for acute ischemic stroke that is localized, does not require the use of thrombolytics, and is capable of quickly recanalizing an occluded vessel. A simulation model was developed to investigate the feasibility of employing high intensity focused ultrasound to induce non-invasive clot lysis through the human skull at frequencies capable of producing a focus small enough to fit within the major vessels of the brain. The results suggest that an array with approximately 16,000 elements would be required to electronically treat all but the most distal sonication targets. The element numbers required for this array are over an order of magnitude higher than what currently exists today and so this study motivates the need for further research into reducing the acoustic pressures required for clot lysis and optimizing array design. The ability of intravascular droplets to lower the acoustic power required for high intensity clot lysis was explored. The application of droplet-enhanced clot lysis was investigated in an embolic rabbit model. Recanalization was demonstrated in 73% of cases at approximately 24% of the acoustic power required without droplets. The results demonstrated that red blood cell extravasations were confined to the acoustic focus, suggesting that a transducer capable of placing the entire focus within a vessel would be able to confine the bioeffect within the same volume. Transcranial focused ultrasound sparse arrays at relatively high frequencies that could produce a tighter focus than the prototypes in existence today were investigated through simulations. The results showed that a hemispherical array with a 10% population of 3 mm elements - 1588 elements in total - would be capable of steering 4 cm in each direction with acceptable grating lobes. These sparse arrays could potentially be well-suited to lower power applications, such as low intensity sonothrombolysis with thrombolytic agents or blood-brain barrier disruption.

Degree

thesis:*
Department dc:contributor.department
Medical Biophysics
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pajek, Daniel
Advisor dc:contributor.advisor
  • Hynynen, Kullervo

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/70427

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Pajek, Daniel. The Application of Transcranial High Intensity Focused Ultrasound to Clot Lysis. 2014. https://hdl.handle.net/1807/70427