University of Toronto
Multimode Spectroscopy for Self-referenced Plasmonic Biosensing
Abstract
dc:description.abstractSurface plasmon resonance (SPR) is an efficient mechanism for biosensing due to its high field intensity and subwavelength confinement. However, the information obtained from these sensors is limited as they only rely on a single measurement at TM polarization. This limitation results in cross sensitivity of the surface plasmon (SP) wave to several parameters such as variations in bulk solution concentration or temperature fluctuations, in addition to the analyte to be measured. In this dissertation the possibility to decouple the aforementioned parameters from the analyte by spectroscopy with more than one mode is investigated. A hybrid plasmonic waveguide (HPWG) and a plasmon waveguide resonance (PWR) sensor are considered for exciting two resonance modes using dual-polarization spectroscopy. These sensors are based on different combinations of a dielectric waveguide and a plasmonic guiding layer. Depending on the overlap of each mode (TE or TM) with the sensing region, each mode exhibits different sensitivity to the measurand. The structural properties of these sensors have been optimized using a genetic algorithm (GA) to ensure optimum performance. Moreover, a method to decouple the interfering surface and bulk effects is presented. The applications of the PWR sensor for refractive index sensing, thin film measurement, and kinetic analysis of protein-nanoparticle interactions are experimentally demonstrated and compared with the conventional SPR sensor. It is demonstrated that for refractive index sensing the TM mode of the PWR sensor has six times smaller refractive index resolution than that of the SPR sensor. To further enhance the functionality of the plasmonic sensors, two grating based designs are proposed which can perform three-mode spectroscopy. The first design contains a one dimensional dielectric grating based SPR sensor (DGSPR) and the second grating sensor contains a one dimensional metallic grating loaded on an SPR sensor (MGSPR). Both designs are optimized with a GA to obtain three resonance modes. A detailed analysis of these designs using numerical and analytical methods is presented. The performance of each mode is compared with that of the conventional SPR sensor. Finally, a method to differentiate three interfering effects is provided.
Degree
thesis:*- Department dc:contributor.department
- Electrical and Computer Engineering
- Year dc:date.issued
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bahrami, Farshid
- Advisors dc:contributor.advisor
-
- Aitchison, James Stewart
- Mojahedi, Mohammad
Subjects
dc:subject × 6Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/70918