Back to search

University of Toronto

The Use of Susceptibility Effects for Tracking and Encoding in MR-guided Interventional Procedures

Abstract

dc:description.abstract

Magnetic Resonance Imaging (MRI) provides volumetric imaging with superior soft tissue contrast and is now standard-of-care for many diagnostic applications. A growing area is the use of MRI for minimally invasive procedures (a.k.a interventions) such as MRI-guided biopsy. In this thesis, the target procedure was placement of a drainage catheter in the upper urinary tract, the technical term for which is nephrostomy. Tracking and visualization of the interventional devices is crucial in achieving a successful outcome of the procedure. This thesis is a study of MRI methodologies to track interventional devices in MRI-guided procedures. A particular focus was the application of magnetic materials used to perturb the main magnetic field, an effect that was used to develop tools and techniques for tracking devices and making images at the device tip. The experiments in Chapter 2 led to the development of a new technique using spectrally selective excitation, which is capable of simultaneously measuring the location and orientation of an interventional device. In Chapter 3, a new mechanism for tracking is proposed based on the magneto-optical effect in nickel nanoparticles, where fiber optics were used to deliver photons from a near infrared (NIR) laser. This development is intended to enable the incorporation of small tracking devices attached to the interventional tools, which can be pulsed on and off using a laser waveform. In Chapter 4, magnetic materials have been used to generate spatial encoding fields at the tip of a device, to generate endoscopic MR images. These results have contributed to the development of tracking devices and to the advancement of MRI acquisition methods for passive tracking in MR-guided procedures, with an outlook towards clinical application in nephrostomy and beyond.

Degree

thesis:*
Department dc:contributor.department
Medical Biophysics
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karimi, Hirad
Advisor dc:contributor.advisor
  • Cunningham, Charles H.

Subjects

dc:subject × 3

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1807/73031

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Karimi, Hirad. The Use of Susceptibility Effects for Tracking and Encoding in MR-guided Interventional Procedures. 2016. https://hdl.handle.net/1807/73031