University of Toronto
Towards Active Image Guidance in X-ray Fluoroscopy-guided Radiotherapeutic and Surgical Interventions
Abstract
dc:description.abstractThere is growing concern regarding the ionizing dose delivered during x-ray fluoroscopy-guided minimally invasive clinical procedures, particularly in interventional cardiology and neuroradiology, and in real-time tumor tracking radiotherapy and radiosurgery. As these image-guided procedures advance and become more complex, the associated radiation-related risks are of concern owing to the duration of treatment. The objective of image guidance is to localize and track objects of interest. An insufficient dose may convey less geometric information which may lead to inaccuracy and imprecision in intervention placement. In this study, a method for achieving the required tracking uncertainty for a given x-ray fluoroscopy-guided interventional procedure using minimal dose is investigated. A simple model is used to demonstrate that a relationship exists between imaging dose and tracking uncertainty. A feedback framework for active image guidance (AIG) is introduced that exploits this relationship to modulate the tube current in order to maintain the required uncertainty for a given interventional procedure. This framework is evaluated in the context of a fiducial tracking problem associated with image-guided radiotherapy in the lung by simulating respiratory motion. A particle filter algorithm is used to robustly track the fiducial as it traverses through regions of high and low quantum noise. Published motion models are incorporated in a tracking test suite to evaluate the dose-localization performance tradeoffs. Additionally, the AIG framework is embodied in a physical prototype and validated in a practical setting. With feedback engaged, the tracking error was found to correlate well with the specified targeting uncertainty. Comparison of the feedback framework with a comparable system employing fixed exposure demonstrated dose savings of up to 29%. The analysis reveals a potentially powerful technique for dynamic optimization of fluoroscopic imaging parameters to control the applied dose by exploiting the tradeoff between tracking uncertainty and x-ray exposure per frame.
Degree
thesis:*- Department dc:contributor.department
- Computer Science
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Siddique, Sami
- Advisors dc:contributor.advisor
-
- Jaffray, David A
- Fiume, Eugene
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1807/73172